8 ELECTRICAL WIRING
8.1 Outdoor Unit Wiring
1) The Specification of Power
Indoor
/
Outdoor unit
Signal wire (mm
2
)
(Weak electric signal)
Circuit Breaker (A)
40
3X4.0
10~16
3-core shielded wire
Outdoor
Unit
Power
Phase
1 Phase
220-240V 50Hz
Power Wiring
(mm
2
)
3X0.75
Capicity(kW)
Voltage and
Frequency
4~16kW
Outdoor
Unit
Indoor
Unit
Power (220-240V~ 50Hz)
or (380-415V 3N~ 50Hz)
Power wiring
(indoor)
Communication Bus
Power (220-240V~ 50Hz)
or (380-415V 3N~ 50Hz)
Switch / Circuit breaker
Switch / Circuit breaker
Leakage protection
switch
Power wiring
(outdoor)
CAUTION
● Please select power source for indoor unit and outdoor unit
respectively.
● The power supply has specified branch circuit with leakage
protector and manual switch.
● Outdoor unit and indoor unit conncet with required power
supply which is 220-240V~ 50Hz or 380-415V 3N~ 50Hz.
● Use 3-core screened wire as indoor and outdoor control wire.
● The installation should comply with relevant national electric
standard.
● Power wiring should be engaged by specialized electrician.
CAUTION
CEquipment complying with IEC 61000-3-12.
● A disconnection device having an air gap contact separation in
all active conductors should be incorporated in the fixed wiring
according to the National Wiring Regulation.
●
The reserved function is indicated in broken line table, users
can select it when necessary.
To prevent interference with communication, increase a magnetic
ring inside and outside communication line (around 1 lap).
CAUTION
Circuit Breaker (A)
32
4~16
Indoor Unit
Power
Phase
Voltage and
Frequency
1-Phase or 3 Phase
220-240V 50Hz
380-415V 50Hz
Power Wiring
(mm
2
)
Indoor Unit /Outdoor Unit
Signal Wire (mm
2
)
(Weak electric signal)
3-core shielded wire
3X0.75
Capicity(kW)
3X2.5(1phase) or 5X2.5(3 phase)
CAUTION
● When power cord is parallel with signal wire, please put them
into separate wire distribution pipes, and leave a proper
distance.
● (Reference distance: It is 300mm when current capacity of
power cord is less than 10A, or 500mm when 50A).
2) Indoor/Outdoor Unit Signal Wire
Wrong connection may cause malfunction.
3) Wiring Connection
Seal the wiring connection with the insulation material , or
the condensing dew will be caused.
8.2 Indoor Unit Wiring
1) Power Supply
*
Flexible cord must meet 60245IEC(H05RN-F) standards.
4~8
12~16
3 Phase
3X2.5
380-415V
50Hz
32
5X2.5
32
Indoor Unit
Outdoor Unit
Power Supply
Power Supply
P Q E
L N
L N
3x4.0mm
P Q E
2
3x0.75mm
(
3-shield wire
)
2
2
3x2.5mm
*
Indoor Unit
Outdoor Unit
Power Supply
Power Supply
P Q E
L1 L2 L3 N
5x2.5mm
P Q E
2
3x0.75mm
(
3-shield wire
)
2
2
5x2.5mm
A B C N