PSC-QS (10/16)
Page 8
Figure 2. General Layout of System Components
2)
Compressor Unit Placement
EarthLinked
®
compressor units may be located inside or outside. If outside, place
compressor unit on a standard HVAC outdoor unit pad. If inside, place it on a level, hard
surface. If the compressor unit is to be fastened down, see Figure 3 for bracket installation.
Avoid placing the compressor unit in or near sound sensitive areas of the residence.
Attic installations must include an auxiliary condensate pan with drain, and suspension from
rafters with suspension isolators.
Clearance around the unit for service is illustrated in Figure 4. However, local codes and
applicable regulations take precedence.
If the compressor unit or other refrigerant-containing system components are located
indoors, they shall be in a location which (1) is an
unoccupied space,
or (2) is served by the
circulating air system, or (3) provides 280 cu. ft. of open space per nominal ton of rated
system capacity. The
2012 International Mechanical Code
defines residential occupancy
as including permanent provisions for living, sleeping, eating, cooking, and sanitation.
Consult local code authorities to define
unoccupied space
for the specific installation.
Summary of Contents for Prime Series
Page 15: ...PSC QS 10 16 Page 15 Figure 8a PSC Compressor Electrical Schematic 230 1 60...
Page 16: ...PSC QS 10 16 Page 16 Figure 8b PSC Compressor Unit Electrical Schematic 230 3 60...
Page 17: ...PSC QS 10 16 Page 17 Figure 9 PSC Air Heating Cooling System Application...
Page 18: ...PSC QS 10 16 Page 18 Figure 10 PSC Air Heating Cooling System Field Wiring Diagram...
Page 26: ...PSC QS 10 16 Page 26 Figure 14 Disassembled Plug Connector...
Page 33: ...PSC QS 10 16 Page 33 Figure 23 PSC Internal Flow Schematic...
Page 34: ...PSC QS 10 16 Page 34 Figure 24 PSC Piping...
Page 36: ...PSC QS 10 16 Page 36 Figure 25 Evacuation of PSC System...
Page 38: ...PSC QS 10 16 Page 38 Figure 26 Initial Charge of PSC System...
Page 40: ...PSC QS 10 16 Page 40 Figure 27 Final Charge of PSC System...
Page 43: ...PSC QS 10 16 Page 43 Figure 31 Start Up Process...
Page 52: ...PSC QS 10 16 Page 52...
Page 53: ...PSC QS 10 16 Page 53...
Page 54: ...PSC QS 10 16 Page 54...
Page 55: ...PSC QS 10 16 Page 55...
Page 56: ...PSC QS 10 16 Page 56...
Page 57: ...PSC QS 10 16 Page 57...