EN
14
LMB
WARNING (UK ONLY)
Mains Connection 230V
The stripper is supplied fitted with a 13 Amp plug top and fuse. If a replacement fuse is
required this must be rated 13A and BS 1362 approved. If in doubt consult a qualified
electrician.
WARNING! This appliance must be earthed. For your total protection it is recommended
that a residual current device (RCD) rated at 30mA should be used in conjunction with
the stripper; load rating MIN 15 Amps, MAX 20 Amps.
If any electrical component is damaged or faulty, it must be replaced by the manufacturer
or its appointed service agents in order to avoid a safety hazard.
•
As the colours of the wires in the supply cord of this appliance may not correspond with
the coloured markings identifying the terminals in your plug, proceed as follows:
•
The wire which is coloured green and yellow must be connected to the terminal in the
plug which is marked with the letter E or by the earth symbol, or coloured green.
•
The wire which is coloured blue must be connected to the terminal which is marked
with the letter N or coloured black.
•
The wire which is coloured brown must be connected to the terminal which is marked
with the letter L or coloured red.
Mains Connection 110V
The stripper is fitted with a 16 Amp industrial plug for insertion into a suitable transformer
or generator supplying 110V a.c. outlet. If the supply cord becomes damaged it must be
replaced with our Part No. PS0155 to avoid a safety hazard.