SERVICING THE VAC MOTOR
CARBON BRUSH REPLACEMENT
1.
Disconnect power cord from power source.
2.
To access the vac motor, remove the screws that
attach the main cover to the head assembly and
set the cover to one side.
3.
Remove the screws that attach the inner cover
to the head assembly and set aside.
4.
Remove the carbon brush assembly by removing
the 2 screws that attach it to the vac motor.
See Figure 1
5.
Slide off the carbon brush connector from the motor
terminal.
See Figure 2
6.
Inspect armature commutator. If it is extremely
pitted, grooved or not concentric then the motor
will need to be replaced or sent to a qualified
service center.
7.
Reverse steps 6 through 4 to install new brush and
housing.
8.
Repeat steps 4 through 7for the other carbon brush.
9.
Reverse steps 3 and 2 for re-assembly.
10. Test for proper operation.
Figure 2
Figure 1
Page 7
(Replacement Carbon Brushes: Part #S8053200)