background image

Page 5

1.  Slide on the two collars as pictured. 

See Figure 1

2. Insert wand into the power head neck until it stops. Slide

the small collar into the neck of the power head. Screw the
large collar onto the powerhead until tight. 

See Figure 2

3. Firmly press the two wands together.

4. Firmly press upper bent wand into the straight wand.

5. Attach two cord hangers to wand and cord.

See Figure 3

6. Evenly attach 3 cord hangers to the hose and cord.

7. Plug power head into the power head receptacle.

See Figure 4

POWER HEAD AND WAND ASSEMBLY INSTRUCTIONS

Locking Collars

Figure 1

Figure 2

Figure 3

Figure 4

Summary of Contents for Hospital S6101HQ-S

Page 1: ...HOSPITAL VAC MODELS S6101HQ T S6101HQ S OPERATIONSANDPARTSMANUAL IMPORTANT READ THIS MANUAL PRIOR TO USE...

Page 2: ...TABLE OF CONTENTS Important Safety Instructions 1 Operation 4 Assembly Instructions 5 Maintenance 6 Servicing the Vac Motor 7 Part Diagrams 8 Warranty Information 14...

Page 3: ...t solvents thinners or other flammable materials DANGER Components used in packaging ex plastic bags can be dangerous keep away from children and animals DANGER Do not pick up flammable fluids dust or...

Page 4: ...y a ground fault interrupter GFCI See Grounding Instructions CAUTION Should extension cords be used ensure that the cable rating is suitable for use with the equipment Do not use the cable coiled as t...

Page 5: ...Page 3...

Page 6: ...ch appropriate cleaning tool For optional power brush attachment see Power Head and Wand Assembly 6 Activate the vacuum by pressing the switch on the vacuum head SET UP AND OPERATION AFTER USE 1 Store...

Page 7: ...the powerhead until tight See Figure 2 3 Firmly press the two wands together 4 Firmly press upper bent wand into the straight wand 5 Attach two cord hangers to wand and cord See Figure 3 6 Evenly att...

Page 8: ...t restore vac performance 1 Disconnect power cord from power source 2 To access the vac motor remove the screws that attach the main cover to the head assembly and set the cover to one side 3 Disconne...

Page 9: ...the 2 screws that attach it to the vac motor See Figure 1 5 Slide off the carbon brush connector from the motor terminal See Figure 2 6 Inspect armature commutator If it is extremely pitted grooved or...

Page 10: ...BLOCK 1 6 S82928AU HANDLE BASE 1 7 S82627 SCREW PHILLIPS M5 X 40 2 8 S82927 HANDLE BLACK 1 9 S81026 SCREW PHILLIPS M5 X 30 1 10 S81006 SCREW PHILLIPS M5 X 20 2 11 S81054 SCREW M5 X 50 2 12 S81026 SCRE...

Page 11: ...EW M3 X 16 2 18 S83383AU PLUG 1 19 S81050 SCREW M5 X 335 6 20 S82738AU MOTORRETAINERTOP 1 21 S80138 FAIRLEAD 1 22 S87708 HEPA FILTER D 224 X 167 H 70 1 23 S82627 SCREW PHILLIPS M5 X 40 6 24 S82591AU M...

Page 12: ...S81026 SCREW PHILLIPS M5 X 30 4 7 S81302 RIVET M5 X 19 4 8 S83602 CLAMP TANK COMPLETE 2 POS PART DESCRIPTION QTY 1 S86045 BASE 1 2 S81005 SCREW M5 X 14 4 3 S86030 CASTER WHEEL 2 4 S82680 SCREW M4 X 1...

Page 13: ...S81026 SCREW PHILLIPS M5 X 30 4 7 S81302 RIVET M5 X 19 4 8 S83602 CLAMP TANK COMPLETE 2 POS PART DESCRIPTION QTY 1 S86045 BASE 1 2 S81005 SCREW M5 X 14 4 3 S86030 CASTER WHEEL 2 4 S82680 SCREW M4 X 1...

Page 14: ...IC MICROSWITCH COMPLETE 1 16 VCA1CMICP MICROSWITCHCOVER 1 17 USE KIT VCSA8VTEL SCREW 1 POS PART DESCRIPTION QTY 18 VCA1CFSNEP TOP COVER 1 19 USE KIT VCSA8VTEL SCREW 4 20 USE KIT VCSA8VTEL SCREW 2 21 V...

Page 15: ...0617 CREVICETOOL 1 D S70004 ROUNDBRUSH 1 E S70616 HAND TOOL 1 F S70632 DOUBLE USE BRUSH 1 G S71685 HOSE 1 TOOLS FILTERS RECOMMENDED SPARE PARTS S80147 Paper Bags Pack of 5 S82881 Hepa Filter Cartridge...

Page 16: ...are prorated for one year EPP will furnish and charge for replacement parts including transportation to the original owner through an EPP authorized service center If the part is returned within 30 d...