The diagnosis and the exclusion for the abnormalities
7
EEPROM error
(EPF)
Fault
Description
detail
error correction
AC drive control
Component error.
Try the function of
"A01 factory
defaults",if it is still
unable eliminated,
please contact us.
EPF
7.1.2
List of Alarm Display
Pressure enduring
test
Radiator overheat
Over rotation moment
of force test
Outside BB
Right/opposite
running order error
RS485 transmission
waiting
AC drive overheat
alarm
RS485 transmission
error
Overvoltage in
stopping
Not enough voltage tested when AC drive stops.
Select test in environment of radiator tempera-
ture≥OH1 test standard, AC drive continue
running.
When the output current of AC drive is>C24
(over rotation moment of force test standard),
select over rotation moment of force, AC drive
continue running.
External BB order input from control circuit
terminal.
It is OFF when right/opposite running order
input over 500ms.
In circumstance of A03(operation mode sellec-
tion)
≥
4, AC drive can not receive data flow
from RS485 when power is on.
AC drive overheat alarm signal is input from
control circuit terminal.
Sellect continue running when RS485
transmission error data transmition break down.
Main circuit EDC voltage surpass overvoltage
test standard when AC drive stops.
display
Content
illustration
Uu
OH1
Ol3
BB
EF
CALL
OH3
CE
OU
EC5000
EF2~8
Error from
terminal
RS485 general
data wire
Error in external control
circuit
Check the input
external,if the error
happen in the
terminal is
unconnect,change
the AC drive.
SPI
Current
Fluctuate too
much
The input power of AC drive
is lack phase or have
unstable in input voltage
Check power in
voltage.
Re-tighten the
input terminal
screw.Or adjusted
basis SPI
SPo
Output lack
phase
AC drive
output lack phase.
1.Check output
wire and check
motor impedance.
2.Re-tighten the
output terminal
screw.
3.Adjust the SPO
standard
Fault
Description
detail
error correction
◎
CE
MEMOBUS
transmition
error
RS485 control data not
received normally.
Check transmition
equipment
or signal
rH
Braking
reactor
component
overheat
Exceed the braking reactor
Temperature
Low down load
capacity.
The connection between AC
drive and digital operator
can’t bulid in 5 seconds after
power is on. MPU external
component error(initial).
Input digital operator,
connector.
check control circuit
wire.
change control insert
board.
Control circuit
error 1
(
ERR
)
Err
The diagnosis and the exclusion for the abnormalities