35
6.2.5.2 Standards Set
The safety standard for different countries can be selected in this
sub-menu.
Australia A, Australia B, Australia C and New Zealand grid codes can be
selected here. cAUSAS4777_2A, cAUSAS4777_2B, cAUSAS4777_2C and
cNZS4777_2 represent Australia A, Australia B, Australia C and New
Zealand standard respectively.
Procedures:
Step1: go to ‘All Set Enable’ in the menu of ‘TECHNICAL SET’ and turn the
status to ‘ON’.
Step2: move to ‘Standard Set’ and get inside
Step3: select the country grid code needed.
Press UP/DOWN to scroll through the national standards, press ENT to
confirm the safety standard, and press ESC to return to the previous
menu.
6.2.5.3 Rated AC Voltage Set
The rated AC voltage can be set up here.
6.2.5.4 AC Output Voltage Limit
Standard
Set
cAusas4777_2A
ALL
SET
Enable
ON
NOTE
: This operation is for maintenance personnel only. Password
is required to access this part!
Rated VAC Set
220V/230V