EV8AQ160-DK
6
BDC- 1-Sep-10
e2v semiconductors SAS 2010
2 Quick start
2.1. Operating procedure
1. Install the Software as describe in section
Software Tools
.
2. Install the FPGA code into ML605 Xilinx evaluation board
FPGA programming
3. Turn OFF the into ML605 Xilinx evaluation board.
4. Connect the demo kit QUAD 8bit on ML605 Xilinx evaluation board.
5. Connect the power supplies of both evaluation boards.
6. Connect the USB cable.
7. Turn ON power supplies of demo kit QUAD 8bit.
8. Turn ON power supplies of ML605 Xilinx evaluation board.
9. Launch the EvalkitQuadAdc8Bits.exe software.
10. Check if current is correct (see chap:
Power
).
11. Turn the mode test ramp active (see chap:
TEST
).
12. Launch acquisition and check if sample signal is correct.
13. Return to normal mode (Turn OFF Test mode).
14. Connect a RF generator on Analog input.
15. Turn on the RF generator.
16. Launch acquisition (see chap
Acquisition
).
2.2. Troubleshooting
2.2.1.
Installation
•
Check that you own rights to write in the directory (administrator right).
•
Check for the available disk space.
•
Check that at USB port is free and properly configured.
o
QUAD 8bit connected to USB 2 driver
Warning: this installation is done for one USB connector only, if you change the USB
connector you need to re-install this USB driver before used.
2.2.2.
Start up procedure
•
Check that supplies are properly powered on and properly connected.
•
Check if the Xilinx FPGA evaluation board ML605 is properly configured with correct software.
•
Check Demo Kit BDC QUAD 8bit is properly plugged into FPGA connector.
•
Check if USB connector is properly plugged.