Camera status
: Get the Camera status register (32bits Integer)
Read function : “
r stat
”;
Returned by the camera : 32bits integer :
Bit 0
: (
StatusWaitForTrigger
) : True if
no trig received from more than 1sec
Bit 1
: (
StatusTriggerTooFast
) :
Missing triggers. Trig signal too fast
Bit 2
: (
StatusSensorConnection
) : True is the Sensor pattern is checked as failed.
Bit 3, 4, 5, 6, 7 : Reserved
Bit 8
: (
StatusWarningOverflow
) : True is an overflow occurs during FFC or Tap balance processing.
Bit 9
: (
StatusWarningUnderflow
) : True is an underflow occurs during FFC or Tap balance processing
Bits 10 : Reserved
Bits 11
: Scrolling Direction : 0 = Forward, 1 = Reverse. Updated only by external CC3 (CameraLink)
Bits, 12, 13, 14, 15 : Reserved
Bit 16
: (
StatusErrorHardware
) : True if hardware error detected
Bits 17 to 31 : Reserved