![e2v Eliixa+ 8k User Manual Download Page 19](http://html1.mh-extra.com/html/e2v/eliixa-8k/eliixa-8k_user-manual_3236368019.webp)
® 8k/4k CL
19
UM 8k/4k CL – REVA – 01/13
e2v semiconductors SAS 2013
6.3
Camera Commands
6.3.1
Information
These values allow to indentify the Camera. They can be accessed in CommCam software in the “Info” section
All these values are fixed in factory and can’t be changed (shaded) except the Camera User ID which can be
fixed by the Customer :
•
Vendor name
(
DeviceVendorName
)
: “e2v”
Read function : “
r vdnm
”;
Returned by the camera : “e2v”, string of 32 bytes (including “/0”)
Can not be written
•
Model Name
(
DeviceModelName
)
: Internal name for GenICam :
Read function : “
r mdnm
”;
Returned by the camera : String of 32 bytes (including “/0”) :
Can not be written
•
Device Manufacturer Info
(
DeviceManufacturerInfo
) : Get Camera ID
Read function : “
r idnb
”;
Returned by the camera : String of 128 bytes (including “/0”)
Can not be written
•
Device Version
(
DeviceVersion
) : Get Camera Hardware version
Read function : “
r dhwv
”;
Returned by the camera : String of 32 bytes (including “/0”)
Can not be written
•
Device Firmware Version
(
DeviceFirmwareVersion
): Get camera synthetic firmware
Read function : “
r dfwv
”;
Returned by the camera : String of 16 bytes (including “/0”)
Can not be written
•
Device SFNC Version : 1.5.0
These Parameters (Major, Minor, Sub Minor) are only virtual ones in order to give the SFNC compliance of
the Camera.
•
Device ID
(
DeviceID
) : Camera Factory identifier ID
Read function : “
r cust
”;
Returned by the camera : String of 128 bytes (including “/0”)
Write function : “
w cust <idstr>
”
•
Device User ID
(
DeviceUserID
) : Camera user identifier ID
Read function : “
r cust
”;
Returned by the camera : String of 128 bytes (including “/0”)
Write function : “
w cust <idstr>
”