U
SER
M
ANUAL
16
K
/8
K
CXP
C
OLOR
–
R
EV
G
–
09/2016
P
A G E
|
24
7.3
Acquisition Control
The Acquisition Control section describes all features related to image acquisition, including the trigger and
exposure control. It describes the basic model for acquisition and the typical behavior of the device.
Feature
CXP @
Size
in
bytes
R/W Description
LinePeriod
0x08400
4
RW
Set line period, from from 1 (0,1µs) to 65535 (6553,5µs), step 1
(0,1µs)
LinePeriodMin
0x08404
4
RO
Get current line period min (0..65535 step 0,1µs)
AcquisitionLineRate
Xml
RO
= 1 / LinePeriod en Hertz
ExposureTime
0x08408
4
RW
Set exposure time, from 1 (0,1µs) to 65535 (6553,5µs), step 1 (0,1µs)
TriggerPreset
0x0840C
4
WO
0
: Set trigger preset mode to Free run timed mode, with exposure
time and line period programmable
(*)
1
: Set trigger preset mode to Triggered mode with exposure time
settings
(**)
2
: Set trigger preset mode to Triggered mode with maximum
exposure time
3
: Set trigger preset mode to Triggered mode with exposure time
controlled by one signal
(**)
4
: Set trigger preset mode to Triggered mode with exposure time
controlled by two signals
5
: Set trigger preset mode to Freerun mode, with max exposure time
and programmable line period
ScanDirectionMode
0x0820C
4
RW
0
: Set scan direction to “forward”
1
: Set scan direction to “reverse”
2
: Set scan direction to “Externally controlled direction via External
Line on I/O Connector (0 : forward, 1 : reverse)
ExternalLine
0x08570
4
RW
0
: Line0
1
: Line1
TriggerTooSlow
0x08418
4
RW
Set/get trigger too slow value in ms
From 1 (1 ms) to 5368 (5368 ms) step 1ms
(*)
N
OT AVAILABLE WHEN
S
ENSOR IS SET IN
“F
ULL
D
EFINITION
E
NHANCED
”
MODE
.
(**)
“F
ULL
E
XPOSURE CONTROL
”
MODE ACTIVATED WHEN
S
ENSOR IS SET IN
“F
ULL
D
EFINITION
E
NHANCED
”
MODE
.
An
Acquisition
is defined as the capture of a sequence of one or many
Frame
(s). This Acquisition mode and
its command is managed by the Frame Grabber.
A
Frame
is defined as the capture of
Width
pixels x
Height
lines.
As for the Acquisition Mode, the
Frame Management
(Start, stop …) is also manage by the Frame Grabber.
The CXP Camera is considered as a LineScan Camera (as in the CameraLink version) then only deals
with the Line/Exposure Triggers.
A
Line
starts with an optional
Exposure
period and ends with the completion of the sensor read out.
The Line/Exposure Triggers can be connected :
Either on the GPIO connector of the Camera (2x Lines Triggers : Line0/1 available if Forward/reverse
command is controlled by software)
Or by the CoaxPess Cable : Only one Trigger available (Line2).
If the single CoaxPress Trigger is used, the Synchronization mode using 2xTriggers can’t be used.