U
SER
M
ANUAL
16
K
/8
K
CXP
C
OLOR
–
R
EV
G
–
09/2016
P
A G E
|
17
3.2.3
Trigger Connector
Camera connector type: Hirose HR10A-7R-5SB or compliant
Cable connector type:
Hirose HR10A-7P-5P (male) or compliant,
Provided with the Camera
IN1/IN2 are connected respectively to Line0/Line1 and allow to get external line triggers or the
forward/Reverse “Live” indication.
On the Connector side, the 120
Ω
termination is validated only if the input is switched in LVDS or RS422.
The electrical schematic is detailed below :
Signal
Pin
LVDS IN1+ / TTL IN1
1
LVDS IN1-
2
LVDS IN2+ / TTL IN2
3
LVDS IN2-
4
GND
5
1
2
3
5
5
4
Receptacle viewed from camera back