E2S Warning Signals

      Impress House, Mansell Road, Acton, London W3 7QH

 

www.e2s.com

 

Tel: +44 (0)208 743 8880

 

Document No. D199-00-001-IS

 

Issue 7

 

13-05-22

 

 

Sheet 7 of 8

 

 

Config. 

Voltage 

Configuration Description 

Features  

Product 
Option 
Identifier 

See documents D190-06-001 for DC schematic diagrams.

 

1a 

DC 

Single Stage Configuration 

 

Line monitoring 

 

Positive Switching 

1b 

DC 

Two Stage Configuration 

 

Common Negative  

 

Positive Switching 

1c 

DC 

Three/Four Stage Configuration 

 

Common Negative  

 

Positive Switching 

DC 

Three/Four Stages. Voltage Free 2nd, 3rd & 
4th Stage Activation Configuration 

 

Common Positive 

 

Customer  Set  H1  &  H2  to  Negative 
Switching  

DC 

Two Stage Configuration 

 

Independent Stage Input 

 

Reverse Polarity Stage Monitoring 

DC 

Two Stage Configuration 

 

Line Stage Monitoring (Use suitable 
monitoring relays/ modules) 

 

Not to be used in reverse polarity 
monitoring 

DC 

Two/Three Stage Voltage Free Activation 
Configuration 

 

DC 

Three/Four Stage Configuration 

 

Independent Stage Input 

 

Line Stage Monitoring (Use suitable 
monitoring relays/ modules) 

 

Positive Switching (Default) 

See documents D190-06-005 for AC schematic diagrams. 

1a 

AC 

Single Stage Configuration 

 

1b 

AC 

Three/Four Stage Configuration 

 

AC 

Two/Three Stage Voltage Free Activation 
Configuration 

 

Table 4: Summary of Wiring Options. 

 
 

9)  End of Line Monitoring (DC Units) 

 
All DC units have a blocking diode fitted in their supply input 
lines.  An  end  of  line  monitoring  diode  or  an  end  of  line 
monitoring resistor can be connected across the +ve and 

–ve 

terminals  in  the  flameproof  chamber.  See  D190-06-001  for 
details.

 

 
If  an  end  of  line  resistor  is  used  it  must  have  a  minimum 
resistance value of 3k3 ohms and a minimum wattage of 0.5W 
or a minimum resistance value of 500 ohms and a minimum 
wattage of 2W. 

 

The resistor must be connected directly across the +ve and -
ve  terminals  as  shown  in  the following  drawing.  The  resistor 
leads should be kept as short as possible.  
 
 
 
 

 
 

 

Figure 10: End of Line Resistor placement. 

 

9.1. Custom DC Multi-Stage End Of Line Monitoring 

  
An optional 12-way terminal module is available to enable up 
to four alarm stages to be activated from three DC voltage 
output channels. The three alarm stage activation inputs can 
be independently monitored. 
  
Refer to Schematic D190-06-001, Config. 6. 
Specify Product option ‘V’ when ordering. 
Spare part code for field installation: SP78-0001 
 

Summary of Contents for STExS1

Page 1: ...A 48Vdc 115mA STExS1RAC230 115Vac 73mA 100 240Vac 50 60Hz 80mA 110 105 230Vac 48mA STExS1FDC024 12Vdc 221mA 11 5 54Vdc 221mA 115 110 24Vdc 185mA 48Vdc 115mA STExS1FAC230 115Vac 73mA 100 240Vac 50 60Hz...

Page 2: ...Marking and Notified Body No 2813 UKCA Marking and Notified Body No 0518 3 2 NEC CEC Ratings Gas Class I All models are approved for use as Alarm Horns also comply with the following standards for sig...

Page 3: ...N60529 5 Special Conditions for Safe Use Repair of the flameproof threaded joints and cemented joints is not permitted Figure 1 Flame Path The plastic horn is not anti static and the metallic enclosur...

Page 4: ...xplosive dust atmospheres The installation of the units must also be in accordance with any local codes that may apply and should only be carried out by a competent electrical engineer who has the nec...

Page 5: ...ranching point temperature may exceed 80 C and therefore suitable heat resisting cables and cable glands must be used with a rated service temperature at least as stated below Table 2 ATEX IECEx UKEx...

Page 6: ...n for AC Units Figure 7 AC PCBA SPL Configuration 8 2 Stage Switching Polarity DC Units Switching from positive switching default to negative switching DC Only NOTE Max supply is 33V DC if higher DC v...

Page 7: ...V See documents D190 06 005 for AC schematic diagrams 1a AC Single Stage Configuration 1 1b AC Three Four Stage Configuration 1 2 AC Two Three Stage Voltage Free Activation Configuration K Table 4 Sum...

Page 8: ...rrent relevant standards ATEX IECEx UKEx Requirements Only EN60079 19 IEC60079 19 Explosive atmospheres Equipment repair overhaul and reclamation EN 60079 17 IEC60079 17 Explosive atmospheres Electric...