Equipment Category 

2G / 2D  

Equipment Level Protection 

Gb, Gc, Db, Dc 

Ambient Temperature Range 

-50°C to +70°C 

IP Rating

IP6X to EN/IEC60079-0 

IP66 to EN60529 

 

5)  Special Conditions for Safe Use 

 
Repair of the flameproof threaded joints and cemented joints 
is not permitted. 
 

 

Figure 1: Flame Path. 

 

The metallic enclosure has a non-conductive coating. These 
may generate an ignition-capable level of electrostatic charges 
under certain extreme conditions. The user should ensure that 
the  equipment  is  not  installed  in  a  location  where  it  may  be 
subjected to external conditions that might cause a build-up of 
electrostatic charges on non-conducting surfaces. 
 
All entries must be fitted with a suitable seal at the interface 
with enclosure. 
 

6)  Product Mounting and Access 

 

6.1.  Location and Mounting 

 

The location of the beacons should be made with due regard 
to the area over which the warning signal must be visible. They 
should only be fixed to services that can carry the weight of the 
unit. 
 
STExB2X21 models shall not be mounted with the lamp down. 
 
The STEx beacons should be securely bolted to a flat surface 
using 9.0mm diameter bolt holes in the base of the unit. See 
figure 2. 

 

Figure 2: Fixing Location for B2 Beacon.

 

 

6.2.  Access to the Flameproof Enclosure 

 

Warning –

 

Hot surfaces. External 

surfaces and internal components 
may be hot after operation, take 
care when handling the equipment. 

 

In order to connect the electrical supply cables to the beacon 
it is necessary to remove the flameproof cover to gain access 
to  the  flameproof  chamber.  To  access  the  Ex  d  chamber, 
loosen  the  M4  grub  screw  on  the  beacon  cover.  Open  the 
enclosure by turning the beacon cover counterclockwise and 
remove  the  cover,  taking  extreme  care  not  to  damage  the 
flameproof threads in the process (See figure 3).   
 

 

Figure 3: Accessing the Explosion Proof Enclosure.

 

 
On completion of the installation, the flameproof threaded joint 
should be inspected to ensure that they are clean and that they 
have not been damaged during installation. 
 
Repair of the flame path / flameproof joints is not permitted.  
 
Ensure that the ‘O’ ring seal is in place. 
 
When  fitting  the  flameproof  cover  ensure  the  thread  is 
engaged correctly. Fully tighten the cover all the way, ensure 
no gap is visible between the cover and base of the beacon 
enclosure. Tighten the M4 grub screw. 
 
 
 

Summary of Contents for STExB2X05

Page 1: ...4Vdc 145mA 150mA STExB2X05AC115 115Vac 110 120Vac 50 60Hz 140mA 200mA STExB2X05AC230 230Vac 220 240Vac 50 60Hz 70mA 100mA STExB2X10DC024 24Vdc 20 28Vdc 605mA 710mA STExB2X10DC048 48Vdc 42 54Vdc 230mA...

Page 2: ...C Db Ta 50 C to 70 C STExB2 X10AC115 X10AC230 Ex db IIC T4 Gb Ta 50 C to 70 C Ex tb IIIC T128 C Db Ta 50 C to 70 C STExB2 X15DC024 X15DC048 Ex db IIC T4 Gb Ta 50 C to 70 C Ex tb IIIC T127 C Db Ta 55...

Page 3: ...Suitable The certification approval has validated continuous use up to 38 C ambient and are for transient use up to 70 C ambient Installation must be carried out in compliance with the National Elect...

Page 4: ...unit STExB2X21 models shall not be mounted with the lamp down The STEx beacons should be securely bolted to a flat surface using 9 0mm diameter bolt holes in the base of the unit See figure 2 Figure...

Page 5: ...rical engineer who has the necessary training 7 2 Cable Selection and Connections When selecting the cable size consideration must be given to the input current that each unit draws see table 1 the nu...

Page 6: ...certified blanking plugs NEC CEC Requirements Only The cable entries have an M20 x 1 5 6H entry thread If the installation is made using cable glands only suitably rated and certified cable glands mu...

Page 7: ...a minimum resistance value of 3k3 ohms and a minimum wattage of 0 5W or a minimum resistance value of 500 ohms and a minimum wattage of 2W The resistor must be connected directly across the ve and ve...

Page 8: ...nd any dust layer removed prior to opening the unit Repair of the flameproof threaded joints and cemented joints is not permitted Potential electrostatic charging hazard Clean only with a damp cloth 1...

Page 9: ...Page left Intentionally blank...

Page 10: ...R DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT S...

Page 11: ...NGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO...

Page 12: ...Netherlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIC T6 T3 Gb II 2D Ex tb IIIC T...

Page 13: ...e and Place of Issue London 03 12 2021 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Page 14: ...0518 Rake Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 2G Ex db IIC T6 T3 Gb II 2D Ex tb IIIC T85 C T137 C Db IP6...

Page 15: ...nd Place of Issue London 24 02 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the ma...

Page 16: ...Page left Intentionally blank...

Reviews: