E2S STExB2X05 Instruction Manual Download Page 10

warning signals

2S

EUROPEAN SAFETY SYSTEMS LTD

IMPRESS HOUSE

MANSELL ROAD

ACTON

LONDON W3 7QH

WWW.E2S.COM

C

THIS DRAWING AND ANY INFORMATION OR DESCRIPTIVE 

MATTER THEREIN IS COMMUNICATED IN CONFIDENCE AND 

IS THE COPYRIGHT PROPERTY OF EUROPEAN SAFETY 

SYSTEMS LTD. NEITHER THE WHOLE OR ANY EXTRACT MAY 

BE DISCLOSED, LOANED, COPIED OR USED FOR 

MANUFACTURING OR TENDERING PURPOSES WITHOUT THEIR 

WRITTEN CONSENT.

EUROPEAN SAFETY SYSTEMS LTD.

AS PER LATEST DATE OF ISSUE SHOWN ABOVE

DRAWING TO BS8888:2000
GEOMETRIC TOLERANCES TO ISO1101:1983
LINEAR DIMENSIONAL TOLS

ANGULAR DIMENSIONAL TOLS

STANDARDS

MOD No.

REASON - INITIAL - DATE

ISSUE

DATE

APPROVED

CHECKED

DATE

DATE

DRAWN

WEIGHT (Kg)

SURFACE FINISH

MATERIAL

ALTERNATIVE MATERIAL

SHEET

SCALE

TITLE

A3

IF IN DOUBT, ASK - 
DO NOT SCALE

ALL DIMENSIONS IN MM

DRAWING NUMBER

A

B

C

D

E

F

G

10

9

G

F

E

7

8

6

5

D

C

1

3

4

2

A

B

D199-06-201

R.N.POTTS

OF

STExB2 X05/X10/X15/X21

NTS 1

2

A

03/07/19

NEW PCBA & FORMAT INTRODUCED
J.S - 22/03/21

INTRODUCTION
RSR - 03/07/19

STExB2 BEACONS

R.N.POTTS

03/07/19

R.S.RAIT

03/07/19

BEACON WIRING DIAGRAMS

DC XENON STExB2 X05, X10, X15 & 21J UNITS
Line Monitoring
Power: +ve & -ve

OPTIONAL LINE MONITORING RESISTOR, CUSTOMER SUPPLIED,  
RECOMMENDED MINIMUM VALUES:

R1

 500Ω MIN, 2W MIN OR 3K3Ω MIN, 0.5W MIN

+ve IN

+ve OUT

-ve IN

-ve OUT

R1

+
+

-
-

INPUT TERMINALS & EOL RESISTOR ADDED
DAH - 17/12/19

C

Summary of Contents for STExB2X05

Page 1: ...4Vdc 145mA 150mA STExB2X05AC115 115Vac 110 120Vac 50 60Hz 140mA 200mA STExB2X05AC230 230Vac 220 240Vac 50 60Hz 70mA 100mA STExB2X10DC024 24Vdc 20 28Vdc 605mA 710mA STExB2X10DC048 48Vdc 42 54Vdc 230mA...

Page 2: ...C Db Ta 50 C to 70 C STExB2 X10AC115 X10AC230 Ex db IIC T4 Gb Ta 50 C to 70 C Ex tb IIIC T128 C Db Ta 50 C to 70 C STExB2 X15DC024 X15DC048 Ex db IIC T4 Gb Ta 50 C to 70 C Ex tb IIIC T127 C Db Ta 55...

Page 3: ...Suitable The certification approval has validated continuous use up to 38 C ambient and are for transient use up to 70 C ambient Installation must be carried out in compliance with the National Elect...

Page 4: ...unit STExB2X21 models shall not be mounted with the lamp down The STEx beacons should be securely bolted to a flat surface using 9 0mm diameter bolt holes in the base of the unit See figure 2 Figure...

Page 5: ...rical engineer who has the necessary training 7 2 Cable Selection and Connections When selecting the cable size consideration must be given to the input current that each unit draws see table 1 the nu...

Page 6: ...certified blanking plugs NEC CEC Requirements Only The cable entries have an M20 x 1 5 6H entry thread If the installation is made using cable glands only suitably rated and certified cable glands mu...

Page 7: ...a minimum resistance value of 3k3 ohms and a minimum wattage of 0 5W or a minimum resistance value of 500 ohms and a minimum wattage of 2W The resistor must be connected directly across the ve and ve...

Page 8: ...nd any dust layer removed prior to opening the unit Repair of the flameproof threaded joints and cemented joints is not permitted Potential electrostatic charging hazard Clean only with a damp cloth 1...

Page 9: ...Page left Intentionally blank...

Page 10: ...R DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT S...

Page 11: ...NGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO...

Page 12: ...Netherlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIC T6 T3 Gb II 2D Ex tb IIIC T...

Page 13: ...e and Place of Issue London 03 12 2021 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Page 14: ...0518 Rake Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 2G Ex db IIC T6 T3 Gb II 2D Ex tb IIIC T85 C T137 C Db IP6...

Page 15: ...nd Place of Issue London 24 02 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the ma...

Page 16: ...Page left Intentionally blank...