Figure 14 - Schematic of SIL 2 system wiring for fault detection in standby mode only 

 2 wire installation 

 
To evaluate the total current drawn from the SIL 2 unit, use the equation below. 
 

 

 

 
 
 
In standby mode, where there is no fault, RLY 1-1 is open. This means the voltage only passes through the customer EOL  resistor 
and the current drawn from the SIL 2 board is 25mA. Therefore, the equation for a No Fault scenario is then: 
 

 

 

 

 
In standby mode, where there is a fault, the circuit is closed. This means the voltage passes through both the customer EOL resistor 
and current sense resistor and the current drawn from the SIL 2 board is 20mA. The customer must first calculate the resistance of 
the two resistors in parallel before applying the currents to the equation. The equation for a Fault scenario is then:   
 

 

 

 
 
 

Table 4:  Resistor combinations and the currents drawn when no faults and faults occur 

 

If multiple SIL 2 alarm horn sounders are to be cabled in series the monitoring connections differ from  that of a single alarm horn 
sounder. For more information see manual D197-00-651-IS available from the E2S website. 

 

 
 
 
 
 
 

(Total Current 

drawn) 

 

I

FR

 

(Current drawn from 

Fault Resistor) 

I

EOL

 

(Current drawn from 

Customer EOL resistor) 

I

SIL

 

(Current drawn 

from SIL board) 

I

NF

 

(Standby Mode, Total Current drawn - No Fault) 

I

FR

 

(0mA) 

I

EOL

 

(See table 4) 

I

SIL

 

(25mA) 

I

F

 

(Standby Mode, Total Current drawn - Fault) 

I

TR

 

(Total Resistance when EOL & FR in parallel) 

I

SIL

 

(20mA) 

Standby 

Mode 

Power Supply Fault Resistor  Customer EOL Resistor 

(Fault Mode Only) 

Current 

drawn 

from SIL 

Board 

Total 

current 

drawn 

Resistor 

Value 

Current 

drawn (

I

FR

)

 

Resistor 

Value 

Current 

drawn (

I

EOL

Total 

resistance 

Current 

drawn (

I

TR

No Fault 

2.2 kΩ

 

0 mA 

2.2 kΩ

 

10.9 mA 

25 mA 

35.9 mA 

Fault 

1.1 kΩ

 

21.8 mA 

20 mA 

41.8 mA 

No Fault 

1.0 kΩ

 

0 mA 

1.0 kΩ

 

24.0 mA 

25 mA 

49.0 mA 

Fault 

500 Ω

 

48.0 mA 

20 mA 

68.0 mA 

No Fault 

2.2 kΩ

 

0 mA 

3.3 kΩ

 

7.3 mA 

25 mA 

32.3 mA 

Fault 

1.3 

kΩ

 

18.2 mA 

20 mA 

38.2 mA 

No Fault 

1.8 kΩ

 

0 mA 

3.9 kΩ

 

6.2 mA 

 

 

25 mA 

31.2 mA 

Fault 

1.2 kΩ

 

19.5 mA 

20 mA 

39.5 mA 

No Fault 

1.8 kΩ

 

0 mA 

4.7 kΩ

 

5.1 mA 

25 mA 

30.1 mA 

Fault 

1.3 kΩ

 

18.4 mA 

20 mA 

38.4 mA 

No Fault 

2.2 kΩ

 

0 mA 

4.7 kΩ

 

5.1 mA 

25 mA 

30.1 mA 

Fault 

1.5 kΩ

 

16.0 mA 

20 mA 

36.0 mA 

Summary of Contents for GNExS1RDC024-S

Page 1: ...nt Max Current Sound Pressure Level dB A Max Nom GNExS1FDC024 S 24Vdc 20 28Vdc 185mA 221mA 115 110 GNExS1RDC024 S 24Vdc 20 28Vdc 185mA 221mA 110 105 Max Tone 4 Nom Tone 44 The table shows the input cu...

Page 2: ...C to 70 C Certificate No SIRA 13ATEX1139X IECEx SIR 13 0029X CSAE 21UKEX1558X Epsilon x Equipment Group and Category II 2G CE Marking and Notified Body No 2813 UKCA Marking and Notified Body No 0518...

Page 3: ...clean and that they have not been damaged during installation Ensure that the O ring seal is in place and undamaged When fitting the flameproof cover ensure the thread is engaged correctly Fully tigh...

Page 4: ...e branching point temperatures may exceed 70 C at entry point 80 C at branching point Therefore suitable heat resisting cables and cable glands must be used with a rated service temperature at least a...

Page 5: ...ed use Negative switching Figure 8 Stage Switching Polarity 8 3 Tone Selection The GNExS Alarm Horn Sounders have 64 different tones that can be selected independently for the first and second stage a...

Page 6: ...ms and a minimum wattage of 2W The resistor must be connected directly across the ve and ve terminals as shown in the following drawing The resistor leads should be kept as short as possible SIL2 line...

Page 7: ...SIL 2 Sounder Unit Monitors Standby mode and Active mode Health status of power supply Sounder correct function and tone pattern The SIL 2 sounder operates as part of a SIL 2 system The sounder will a...

Page 8: ...quire further investigation please contact your local E2S representative Commissioning System Functional start up of System Normally in reverse polarity mode When Commissioning system the power must n...

Page 9: ...ounder check on pattern generation and signal output checks Important Only tones use tones that are stated as SIL 2 approved for the SIL 2 application Ensure that the unit is set to one of these tones...

Page 10: ...rom the circuit Note a cable short circuit will not be detectable in this configuration For one unit only Sounder power supply terminal block Current drawn mA Active Mode 190mA Standby Mode 25mA SIL2...

Page 11: ...multiple SIL 2 alarm horn sounders are to be cabled in series the monitoring connections differ from that of a single alarm horn sounder For more information see manual D197 00 651 IS available from t...

Page 12: ...ion B pins 2 3 linked Places power supply terminal Fault resistor RLY 1 2 in circuit As used in 2 Wire Configuration Figure 16 J2 Header pin positions Fault Resistor FR 15 4 SIL 2 Hard Reset Function...

Page 13: ...nput GNExS1FDC024 S GNExS1RDC024 S Failure to Sound Integrity in respect of failure to release SIL 2 Total Failure rate 0 447 pmh hazardous failure rate revealed 0 443 pmh hazardous failure rate unrev...

Page 14: ...The values of resistors available are shown in table 6 below Code Resistor Value Default resistor coding as follows GNExS1FDC024AB1S1R AFZ Example of a custom requirement resistor coding GNExS1FDC024...

Page 15: ...0 1 0 0 1 0 1 1 0 0 1 0 0 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 1 0 1 1 1 0 1 0 1 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 1 0 1 1 0 0 1 1 1 1 0 0 1 0 0 0 1...

Page 16: ...OUT Common ve IN Common ve OUT Stage 2 ve Stage 1 ve IN Stage 1 ve OUT Common ve IN Common ve OUT Stage 2 ve Stage 3 ve EOL EOL S2 EOL S2 S3 Stage 1 ve IN Stage 1 ve OUT Stage 1 ve IN Stage 1 ve OUT...

Page 17: ...S NTS SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED Stage 2 ve Common ve IN Common ve OUT Stage 1 ve OUT Stage 3 ve Stage 1 ve IN H2 H1 OF 2 2 EOL S2 S3 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUP...

Page 18: ...y No 2813 CSA Group Netherlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIB or IIC T...

Page 19: ...te and Place of Issue London 23 12 2020 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the...

Page 20: ...ipment II 2G Ex db IIB or IIC T3 T4 T5 or T6 Gb Standards applied EN 60079 0 2018 EN 60079 1 2014 A C 2018 Directive 2014 30 EU Electromagnetic Compatibility Directive EMC Standards applied EN 61000 6...

Reviews: