background image

 
 
 
 
 
 

 
 
 
 
 
 
 
 

E2S

 

Telephone:

 

+44

 

(0)20

 

8743

 

8880

 

Fax:

 

+44

 

(0)20

 

8740

 

4200

 

Email:

 

[email protected]

 

www.e2s.com

 

DC

078_Issue_E

 ‐ 

Page

 

1

 

of

 

1

 ‐ 

QAF_252_Issue_5

 

 
 
 

Martin

 

Streetz

 

Document

 

No.:

 

DC

078_Issue_E

 

Quality

 

Assurance

 

Manager

 

Date

 

and

 

Place

 

of

 

Issue:

 

London,

 

23/12/2020

 

EU

 

Declaration

 

of

 

Conformity

 

Manufacturer:

   

 

European

 

Safety

 

Systems

 

Ltd.

 

 

 

 

Impress

 

House,

 

Mansell

 

Road,

 

Acton

 

 

 

 

London,

 

W3

 

7QH

 

 

 

 

United

 

Kingdom

 

 

Authorised

 

Representative:

 

E2S

 

Warnsignaltechnik

 

UG

 

 

 

 

Charlottenstrasse

 

45

51

 

 

 

 

72764

 

Reutlingen

 

 

 

 

Germany

 

 

Equipment

 

Type:

 

GNExCP7

BG,

 

GNExCP7

PB,

 

GNExCP7

PM,

 

GNExCP7

PT

 

 

Directive

 

2014/34/EU:

 

Equipment

 

and

 

Protective

 

Systems

 

for

 

use

 

in

 

Potentially

 

Explosive

 

Atmospheres

 

(ATEX)

 

Notified

 

Body

 

for

 

EU

 

type

 

Examination

 

(Module

 

B):

 

UL

 

International

 

Demko

 

A/S

 

Notified

 

Body

 

No.:

 

0539

 

Borupvang

 

5A,

 

2750

 

Ballerup,

 

Denmark

 

EU

type

 

Examination

 

Certificate

 

(Module

 

B):

 

DEMKO

 

19

 

ATEX

 

2101X

 

Notified

 

Body

 

for

 

Quality

 

Assurance

 

Notification

 

/

 

Conformity

 

to

 

EU

type

 

based

 

on

 

quality

 

assurance

 

of

 

the

 

production

 

process

 

(Module

 

D):

 

Sira

 

Certification

 

Service

 

Notified

 

Body

 

No.:

 

2813

  

CSA

 

Group

 

Netherlands

 

B.V,

 

Utrechtseweg

 

310,

 

6812

 

AR,

 

Arnhem,

 

Netherlands

 

Quality

 

Assurance

 

Notification

 

(Module

 

D):

 

SIRA

 

05

 

ATEX

 

M342

 

Provisions

 

fulfilled

 

by

 

the

 

equipment:

 

II

 

2G

 

Ex

 

d

 

IIC

 

T6…T5

 

Gb

 

II

 

2D

 

Ex

 

tb

 

IIIC

 

T90°C….T80°C

 

Db

 

Standards

 

applied:

 

EN

 

60079

0:2018

 

EN

 

60079

1:2014

 

EN

 

60079

31:2014

 

IP6X

 

Dust

 

Protection

 

to

 

EN60079

0

 

/

 

EN60079

31

 

Directive

 

2014/30/EU:

 

Electromagnetic

 

Compatibility

 

Directive

 

(EMC)

  

Standards

 

applied:

 

EN

 

61000

6

1:2007

 

EN

 

61000

6

2:2005

 

EN

 

61000

6

3:2007

 

/

 

A1:2011

 

/

 

AC:

 

2012

 

EN

 

61000

6

4:2007

 

/

 

A1:

 

2011

 

Directive

 

2011/65/EU:

 

Restriction

 

of

 

the

 

use

 

of

 

certain

 

hazardous

 

substances

 

in

 

electrical

 

and

 

electronic

 

equipment

 

(RoHS)

 

The

 

product

 

and

 

all

 

the

 

components

 

contained

 

within

 

it

 

are

 

in

 

accordance

 

with

 

the

 

restriction

 

of

 

the

 

use

 

of

 

hazardous

 

substances

 

in

 

electrical

 

and

 

electronic

 

equipment,

 

including

 

amendment

 

by

 

Directive

 

2015/863/EU.

 

Regulation

 

(EC)

 

1907/2006:

 

Registration,

 

Evaluation,

 

Authorisation

 

and

 

Restriction

 

of

 

Chemicals

 

(REACH)

 

The

 

product

 

and

 

all

 

the

 

components

 

contained

 

within

 

it

 

are

 

free

 

from

 

substances

 

of

 

very

 

high

 

concern.

 

Other

 

Standards

 

and

 

Regulations

 

EN

 

60529:1991

 

+

 

A1:2000

 

+

 

A2:2013.

 ‐ 

Degrees

 

of

 

protection

 

provided

 

by

 

enclosures

 

(IP

 

code)

 

 

enclosure

 

rated

 

IP66/67

 

 

On

 

behalf

 

of

 

European

 

Safety

 

Systems

 

Ltd.,

 

I

 

declare

 

that,

 

on

 

the

 

date

 

the

 

equipment

 

accompanied

 

by

 

this

 

declaration

 

is

 

placed

 

on

 

the

 

market,

 

the

 

equipment

 

conforms

 

with

 

all

 

technical

 

and

 

regulatory

 

requirements

 

of

 

the

 

above

 

listed

 

directives,

 

regulations

 

and

 

standards.

 

 

This

 

Declaration

 

is

 

issued

 

under

 

the

 

sole

 

responsibility

 

of

 

the

 

manufacturer.

 

Summary of Contents for GNE CP7-BG-D Series

Page 1: ... 1 0A Max 24Vdc Max 3 33A Max Class Div Zone 5 0 Max ATEX IECEx UKEx Table 1 Electrical Ratings 2 Warnings WARNINGS USE COVER BOLTS CLASS A4 70 DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING HAZARD SEE INSTRUCTIONS FOR INDOOR OR OUTDOOR USE TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES CONDUIT RUNS MUST HAVE A SEALING FITTING CONNECTED WITHIN 2 INCHE...

Page 2: ...to 70 C Class Zone Ratings for US NEC Model No Rating GNExCP7 BG S Class I Zone 1 AEx db IIC T6 Gb Ta 55 C to 70 C Zone 21 AEx tb IIIC T110 C Db Ta 55 C to 70 C GNExCP7 BG D Class I Zone 1 AEx db IIC T5 Gb Ta 55 C to 70 C Class I Zone 1 AEx db IIC T6 Gb Ta 55 C to 65 C Zone 21 AEx tb IIIC T135 C Db Ta 55 C to 70 C Class Zone Ratings for Canada CEC Model No Rating GNExCP7 BG S Ex db IIC T6 Gb X Ta ...

Page 3: ...sive dust atmospheres 5 Specific Conditions for Safe Use The stainless steel lift flap is not earthed and may generate an ignition capable level of electrostatic charges It has a max capacitance of 6 33pF according to CSA C22 2 NO 60079 0 UL 60079 0 2017 clause 7 5 or EN IEC60079 0 clause 7 5 Equipment is permitted to be wall mounted only in vertical position The enclosure base is permitted in two...

Page 4: ...tion of Cable Cable Glands Blanking Elements Adapters ATEx IECEx UKEx Installations The equipment must only be installed by suitably qualified personnel in accordance with the latest issues of the relevant standards EN60079 14 IEC60079 14 Explosive atmospheres Electrical installations design selection and erection EN60079 10 1 IEC60079 10 1 Explosive atmospheres Classification of areas Explosive g...

Page 5: ...d as close as practical to the wall of the enclosure but in no case more than the size of the conduit or 2 of enclosure whichever is the lesser Electrical connections are to be made into the PCB terminal blocks DIN rail provided Internal earthing connections should be made to the Internal Earth terminal on the PCBA The earth conductor should be at least equal in size and rating to the incoming pow...

Page 6: ... sectional areas such as 2 5mm 13 Testing unit operation The break glass unit can be tested without the need to break replace the frangible glass element A test key Plastic Key Supplied with unit is used to mechanically drop the glass down activating the switch The test key is inserted in the test cam and rotated clockwise by an angle of 90º the glass element will visibly drop down in the viewable...

Page 7: ...The following table 2 shows limitations for all possible variations EOL End of line device resistor ExxxR diode ED1 zener ExxxZ Series In line device resistor SxxxR diode SD1 zener SxxxZ LED Microswitch 1 M S 1 Microswitch 2 M S 2 Table 2 EOL and Series Devices limits The unit can be wired with a maximum of 4 module devices see wiring diagram D202 06 211 Note The maximum voltage stated must not be...

Page 8: ...in Operated condition Terminals 4 5 7 8 closed Terminals 4 5 6 open COM N O N C EOL SER NOTE These can be fitted either by customer or pre installed by E2S at point of order When fitting diodes or zener diodes polarity across devices must be observed Resistor polarity is unimportant SERIES EOL Wiring option shown with EOL series devices acting in parallel 3A Circuit as shown in Unoperated conditio...

Page 9: ... 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 COM N O N C COM N O N C COM N O N C COM N O N C Standard Unit showing positions of optional Series and EOL Devices 1 2 3 4 5 6 M S 1 M S 2 7 8 N O COM 4A Circuit as shown in Unoperated condition Terminals 1 4 M S 1 and 5 8 M S 2 open Terminals 1 3 M S 1 and 5 7 M S 2 closed N C N O COM N C 1 2 3 4 5 6 M S 1 M S 2 7 8 N O COM EOL 4B Circuit as shown in Operated condit...

Page 10: ... M S 2 7 8 N O COM 4A Circuit as shown in Unoperated condition Terminals 1 4 M S 1 and 5 8 M S 2 open Terminals 1 3 M S 1 and 5 7 M S 2 closed N C N O COM N C 1 2 3 4 5 6 M S 1 M S 2 7 8 N O COM EOL 4B Circuit as shown in Operated condition Terminals 1 4 M S 1 and 5 8 M S 2 closed Terminals 1 3 M S 1 and 5 7 M S 2 open N C N O COM N C SER EOL SER EOL 4A Circuit as shown in Unoperated condition Ter...

Page 11: ...1 2 3 1 2 3 M S 1 M S 2 5B Circuit as shown in Operated condition Terminals 1 2 M S 1 and 4 5 M S 2 open Terminals 1 3 M S 1 and 4 6 M S 2 closed R N POTTS Optional Single or Double Microswitch Circuit shown with Double Microswitch Unit un operated GNExCP7 PCB Version Devices selected only as example On M S 1 Series resistor and EOL Zener diode On M S 2 EOL resistor with no series device GNExCP7 S...

Page 12: ...quipment II 2G Ex d IIC T6 T5 Gb II 2D Ex tb IIIC T90 C T80 C Db Standards applied EN 60079 0 2018 EN 60079 1 2014 EN 60079 31 2014 IP6X Dust Protection to EN60079 0 EN60079 31 Directive 2014 30 EU Electromagnetic Compatibility Directive EMC Standards applied EN 61000 6 1 2007 EN 61000 6 2 2005 EN 61000 6 3 2007 A1 2011 AC 2012 EN 61000 6 4 2007 A1 2011 Directive 2011 65 EU Restriction of the use ...

Page 13: ... d IIC T6 T5 Gb II 2D Ex tb IIIC T90 C T80 C Db Standards applied EN 60079 0 2018 EN 60079 1 2014 EN 60079 31 2014 IP6X Dust Protection to EN60079 0 EN60079 31 Directive 2014 30 EU Electromagnetic Compatibility Directive EMC Standards applied EN 61000 6 1 2007 EN 61000 6 2 2005 EN 61000 6 3 2007 A1 2011 AC 2012 EN 61000 6 4 2007 A1 2011 Directive 2011 65 EU Restriction of the use of certain hazard...

Reviews: