background image

 

 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH

 

www.e2s.com

 

Tel: +44 (0)208 743 8880

 

Document No. D210-00-681-IS

 

Issue 5

 

09-05-2023

 

 

Sheet 7 of 8

 

 

 

BExCTS110-05D DC 

 

Fig. 9b Location of Volume Control Potentiometer   

 

14.  Interchangeable & Spare Parts 

 

 

The  beacon  cover  is  interchangeable,  contact  E2S  Ltd  for  a 
replacement cover available in various colours.  

 

To change the cover, unscrew the M5 socket head screws and 
remove the M5 screws, M5 spring & flat washers.  

 

Fig. 10 Removal of cover 

 

Remove  the  guard  and  replace  the  old  cover  with  the  new 
cover.  

 

Fig. 11 Changing of cover 

 

Fit the guard back on to the cover and casting, align the holes 
of  the  guard,  cover  and  casting.  To  reattach  the  cover,  the 
fixings MUST be in the order shown in figure 12.    

 

Fig. 12 Cover and Guard Fixtures 

 

15  Maintenance, Overhaul & Repair 

 

Maintenance,  repair  and  overhaul  of  the  equipment  should 
only  be  carried  out  by  suitably  qualified  personnel  in 
accordance with the current relevant standards: 

 

EN60079-19 
IEC60079-19 

Explosive atmospheres - Equipment 
repair, overhaul and reclamation 

 

EN 60079-17 
IEC60079-17 

Explosive atmospheres - Electrical 
installations inspection and maintenance 

 

The  acoustic  horn  is  made  out  of  ABS  plastic,  therefore  to 
avoid a possible ELECTROSTACTIC CHARGE the unit must 
only be cleaned with a damp cloth. 

 

Units  must  not  be  opened  while  an  explosive  atmosphere  is 
present. 

 

If  opening  the  unit  during  maintenance  operations  a  clean 
environment must be maintained and any dust layer removed 
prior to opening the unit. 

 
 
 

 
 

 

 

Warning 

– Hot surfaces. External surfaces 

and internal components may be hot after 
operation, take care when handling the 
equipment. 
 

M5x16 Hex Socket Screw 
 
M5 Spring Washer 
 
M5 Plain Washer 
 
Guard 
 
Cover 
 

M5x16 Hex 
Socket Screw 

Old 
Cover 

New 
Cover 

Summary of Contents for BExCTS110-05D-P

Page 1: ...126V BExCTS110 05DPAC230 BExCTS110 05DPAC230 R 230Vac 56mA 55mA 253V Max Tone 4 Nom Tone 44 The table shows the input current taken by the various units The current levels shown above are for the 440H...

Page 2: ...s air mixture not likely to occur in normal operation and if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Temperature Classification for Gas Applicati...

Page 3: ...it cannot move in service Fig 1a Fixing Location for Combined Flare Fig 1b Fixing Location for Combined Radial 7 Access to the Flameproof Enclosure To access the Ex d chamber remove the four M6 hexago...

Page 4: ...the stainless steel M4 flat washer is between the incoming earth wire and the enclosure Internal earthing connections should be made to the Internal Earth terminal in the base of the housing using a...

Page 5: ...g Diagram Fig 5a Sounder AC Terminals Fig 5b Beacon AC Terminals 12 DC Wiring Four connections must be made to the BExCTS110 05D DC unit A power supply input cable should enter the enclosure via one o...

Page 6: ...cb see figures 5a 7a The Telephone Selection Table on page seven shows the switch positions 1 4 for the country setting and switch 5 for the beacon continuous or pulse mode and switch 6 for the sounde...

Page 7: ...ixtures 15 Maintenance Overhaul Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards EN6...

Page 8: ...etting 1 2 3 4 5 6 Australia Ireland New Zealand Singapore South Africa UK 0 0 0 0 Belgium Canada Cyprus Hong Kong Spain Turkey USA 1 0 0 0 Czech Republic Finland France Germany Greece Italy Luxemburg...

Page 9: ...mittent 660Hz 1 8s on 1 8s off 1 0 0 0 1 0 2 5 19 1400Hz to 1600Hz sweeep up over 1s 0 1 0 0 1 0 2 5 1600Hz to 1400Hz sweep down over 0 5s 20 Continuous 660Hz 1 1 0 0 1 0 2 5 21 Alternating 554 440Hz...

Page 10: ...DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D210...

Page 11: ...ISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D210 06 685 R S RAIT B ISARD R...

Page 12: ...cation Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 2813 CSA Group Netherlands B V Utrechtseweg 310 6812 AR Arnhem Ne...

Page 13: ...te and Place of Issue London 21 05 2020 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the...

Page 14: ...X2639X Notified Body for Quality Assurance Notification Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 0518 Rake Lane E...

Page 15: ...nd Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the ma...

Page 16: ...Page left Intentionally blank...

Reviews: