background image

 

 

 

 

E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: [email protected] 

www.e2s.com 

DC-106_Issue_A (BExCS)- Page 1 of 2 - QAF_252_Issue_5

 

UKCA Declaration of Conformity 

Manufacturer:   

 

European Safety Systems Ltd. 

 

 

 

Impress House, Mansell Road, Acton 

 

 

 

London, W3 7QH 

 

 

 

United Kingdom 

 

Equipment Type:  

 

BExCS110-05D, BExDCS110-05D, BExCS110-05D-R, BExDCS110-05D-R, 

 

 

 

BExCS110-05D-P, BExDCS110-05D-P, BExCS110-05D-R-P, BExDCS110-05D-R-P, 

 

 

 

BExCL15-05D, BExDCL15-05D, BExCL15-05D-R, BExDCL15-05D-R, 

 

 

 

BExCL15-05D-P, BExDCL15-05D-P, BExCL15-05D-R-P, BExDCL15-05D-R-P, 

 

 

 

BExCTS110-05D, BExDCTS110-05D, BExCTS110-05D-R, BExDCTS110-05D-R, 

 

 

 

BExCTS110-05D-P, BExDCTS110-05D-P, BExCTS110-05D-R-P, BExDCTS110-05D-R-P, 

 

 

 

BExCS110-L1D, BExDCS110-L1D, BExCS110-L1D-R, BExDCS110-L1D-R 

 

 

 

BExCS110-L2D, BExCS110-L2D-R, BExCA110-05D-P 

 

Directive  UKSI 2016:1107 (as amended by UKSI 2019:696) – Schedule 3A, Part 1 : Product or Protective System Intended for use in Potentially Explosive Atmospheres  

(UKCA) 

 

Notified Body for UK type Examination (Module B): 

UL International (UK) Ltd 

Notified Body No.: 0843 

Unit 1-3 Horizon Kingsland Business Park, Wade Road, 

Basingstoke, Hampshire RG24 8AH UK 

UK-type Examination Certificate (Module B): 

UL21UKEX2639X 

Notified Body for Quality Assurance Notification / Conformity to EU-type 

based on 

quality assurance of the production process (Module D): 

Sira Certification Service 

Notified Body No.: 0518 

Rake Lane, Eccleston, Chester CH4 9JN, UK 

Quality Assurance Notification (Module D): 

CSAE 22UKQAN0046 

Provisions fulfilled by the equipment: 

II 2G Ex db IIB T5…T4 Gb 

II 2D Ex tb IIIC T70°C…T125° Db 

IP6X Dust Protection to EN60079-0 / EN60079-31 

Standards applied: 

EN IEC 60079-0: 2018 

EN 60079-1: 2014 

EN 60079-31: 2014 

Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC)  

Standards applied: 

EN 61000-6-1:2007 

EN 61000-6-2:2005 

EN 61000-6-3:2007 / A1:2011 / AC: 2012 

EN 61000-6-4:2007 / A1: 2011 

Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) 
The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and electronic 

equipment, including amendment by Directive 2015/863/EU.

 

Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) 

The product and all the components contained within it are free from substances of very high concern. 

Other Standards and Regulations 

EN 60529:1991 / A1:2000 / A2:2013 - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66/67 

 

 

Summary of Contents for BExCTS110-05D-P

Page 1: ...126V BExCTS110 05DPAC230 BExCTS110 05DPAC230 R 230Vac 56mA 55mA 253V Max Tone 4 Nom Tone 44 The table shows the input current taken by the various units The current levels shown above are for the 440H...

Page 2: ...s air mixture not likely to occur in normal operation and if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Temperature Classification for Gas Applicati...

Page 3: ...it cannot move in service Fig 1a Fixing Location for Combined Flare Fig 1b Fixing Location for Combined Radial 7 Access to the Flameproof Enclosure To access the Ex d chamber remove the four M6 hexago...

Page 4: ...the stainless steel M4 flat washer is between the incoming earth wire and the enclosure Internal earthing connections should be made to the Internal Earth terminal in the base of the housing using a...

Page 5: ...g Diagram Fig 5a Sounder AC Terminals Fig 5b Beacon AC Terminals 12 DC Wiring Four connections must be made to the BExCTS110 05D DC unit A power supply input cable should enter the enclosure via one o...

Page 6: ...cb see figures 5a 7a The Telephone Selection Table on page seven shows the switch positions 1 4 for the country setting and switch 5 for the beacon continuous or pulse mode and switch 6 for the sounde...

Page 7: ...ixtures 15 Maintenance Overhaul Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards EN6...

Page 8: ...etting 1 2 3 4 5 6 Australia Ireland New Zealand Singapore South Africa UK 0 0 0 0 Belgium Canada Cyprus Hong Kong Spain Turkey USA 1 0 0 0 Czech Republic Finland France Germany Greece Italy Luxemburg...

Page 9: ...mittent 660Hz 1 8s on 1 8s off 1 0 0 0 1 0 2 5 19 1400Hz to 1600Hz sweeep up over 1s 0 1 0 0 1 0 2 5 1600Hz to 1400Hz sweep down over 0 5s 20 Continuous 660Hz 1 1 0 0 1 0 2 5 21 Alternating 554 440Hz...

Page 10: ...DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D210...

Page 11: ...ISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D210 06 685 R S RAIT B ISARD R...

Page 12: ...cation Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 2813 CSA Group Netherlands B V Utrechtseweg 310 6812 AR Arnhem Ne...

Page 13: ...te and Place of Issue London 21 05 2020 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the...

Page 14: ...X2639X Notified Body for Quality Assurance Notification Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 0518 Rake Lane E...

Page 15: ...nd Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the ma...

Page 16: ...Page left Intentionally blank...