background image

Info

Distance

MAM filter length

MAM filter border

hysterese width

[mm]

env. avg.count

1; 8 ; 16

low pass filter

[s]

max. fill speed

[mm/s]

ZF average

an  /  aus

max. drain speed

[mm/s]

unfiltered dist.
raw

[mm]

Envelope

envelope
statistics

mapping adder

envelope
smoothing

mapping scan
rate

[dB]

edge detect. mode

front; behind;

middle of echo

first echo factor

[dB]

tank bottom det.

aus; an

HF module

• µP II.1

• µP II.2

• µPIII.1

• µPIII.2

zero distance

[mm]

antenna type

rod; horn; dish;
planar

plausible funct.

aus; an

D/A adjust 4 mA

not PROFIBUS PA

D/A adjust
20 mA

not PROFIBUS PA

plausible funct.
max. delta

plausible funct.
max. delta

[mm]

plausible funct.
upper area

[mm]

display version

VU331 XX

calc. cycle time

[ms]

software version
application

parameter vers.
application

HW fail counter

inactive length

[mm]

debug index 1

debug index 2

debug value

error state
algorithms

state
algorithms

total length

[mm]

max. measuring
distance

[m]

ampl. reference
pulse

[dB]

pos. reference
pulse

[mm]

min. amplitude

tank bot. detec.

[dB]

max. level

tank bot. detec.

[mm]

FEF threshold

[dB]

FEF at near
distance

[dB]

FEF distance
far

[mm]

FEF distance
near

[mm]

FEF edge

[dB]

present FEF

[dB]

fill / drain speed

[mm / s]

mapping
average

FAC adder

[dB]

FAC scan rate

range factory
map

[m]

pres. micro fact.

temp. of electr.

[C]

fact. map. valid

an; aus; löschen

edge parameter

[dB]

cust. map valid

not active; active

trig. fail count

fact. map valid

not active; active

module frequen.

[MHz]

envelope
energy

[dB]

present edge
parameter

[dB]

Mapping

Edge

First echo

Tank bottom
detection

Module

Antenna
table

present
amplitude

amplitude over
mapping

amplitude
over FAC

unfiltered
distance

present
edge parameter

present FEF
first echo factor

device name
FMR53x

unfiltered dist.
fine

[mm]

order code

unfiltered dist.
phase

[mm]

0D

0D0

0D1

0D2

0D3

0D4

0D5

0D6

0D7

0D8

0D9

0DC

0DD

0DF

back to

function group

back to

function group

back to

function group

back to

function group

back to

function group

back to

function group

back to

function group

back to

function group

back to

function group

back to

function group

back to

function group

back to

function groupl

0               1                2               3               4               5               6              7               8                9

Micropilot S, service matrix HART  (display module)

System 1

System 2

Debug

0D00

0D10

0D20

0D30

0D40

0D50

0D60

0D70

0D80

0DC0

0DD0

0DF0

0D21

0D01

0D02

0D03

0D11

0D12

Service

SM09F/00/05.02

software version 2.0

Algorithm 1

IC default value

quali calc. PD

anal. phase state

aus; an

present PD

[mm]

IC save begin

[mm]

IC save end

[mm]

IC state

Algorithm 2

fine envelope
variante

aut. base gain

aus; an

base gain val.

automatic gain

aus; an

far distance gain

[mm]

near dist. gain

[mm]

pres. gian value

distance gain

[mm]

gain settings

IC pres. value

IC used value

0DA

0DB

back to

function group

back to

function group

back to

function groupl

0D90

0DA0

0DB0

0DA1

0D91

0D92

Summary of Contents for Micropilot S FMR 53 Series

Page 1: ...die Reparatur eines Ger tes zu dokumentieren Hierzu geh rt die Angabe der Ger te Seriennummer Reparaturdatum Art der Reparatur und ausf hrender Techniker 0 1 2 0 1 2 1 6 2 7 3 4 5 11 10 9 8 12 12 ENDR...

Page 2: ...em Reset auf die Werkseinstellungen r ckzusetzen In der Diagnose Ebene im Feld 0A3 die Zahl 333 eingeben Gegen unbeabsichtigtes ndern der eingestellten Ger tedaten sollte die Parametrierung verriegelt...

Page 3: ...Punkt Auswahl Messwert 00 000 12 ton 13 m 14 ft 15 mm 16 inch 17 none Kommunikations adresse 0 15 wenn 0 dann Multidropfunktion Stromausgang auf 4 mA fixiert aktueller Fehler letzter Fehler l sche le...

Page 4: ...hen edge parameter dB cust map valid not active active trig fail count fact map valid not active active module frequen MHz envelope energy dB present edge parameter dB Mapping Edge First echo Tank bot...

Page 5: ...im Bypass verl ngerter Markierungspunkt steht 90 zum Zulauf gilt auch f r Hornantenne 90 Beh lter Bypass Ausrichtung im Schwallrohr Verl ngerter Markierungspunkt in Richtung der Schlitzreihe Beh lter...

Page 6: ...Endress Hauser Maulburg...

Page 7: ...lot must again be tested and sealed by an official at commissioning Philips screw driver size 1 flat screwdriver for M3 M4 unplug tool for antenna plug order no 5200 7646 Allen wrench AF 2 5 AF 4 AF 5...

Page 8: ...nk It is recommended to reset the instrument to the factory settings before the calibration enter 333 in field 0A3 of the diagnostics level The configuration should be locked against unwanted changes...

Page 9: ...0 12 ton 13 m 14 ft 15 mm 16 inch 17 none communication address 0 15 if 0 then multidrop function current output fixed at 4 mA present error previous error clear last error keep erase reset x for rese...

Page 10: ...hen edge parameter dB cust map valid not active active trig fail count fact map valid not active active module frequen MHz envelope energy dB present edge parameter dB Mapping Edge First echo Tank bot...

Page 11: ...gnment in bypass marker point is offset to T s by 90 also applies to horn antenna 90 tank bypass Alignment in stilling well marker points toward slots tank stilling well 90 EN DR ES S HA US ER MI CR O...

Page 12: ...Endress Hauser Maulburg...

Reviews: