MISCELLANEOUS
48
site is locked (“x” is the current site number). To unlock the site, press the
Lock switch again and “UNLOCK” is momentarily displayed.
When locked on a site, it is still possible to search for a different site
using the site search function described in the preceding section. When a
new site is found, the radio is then locked on that site.
MISCELLANEOUS
Supervisory Tones
Single Beep (Alert Tone)
•
Power was turned on and a successful power-up sequence occurred (see
page 15).
•
The time-out timer is about to expire or the penalty timer has expired
(page 17 and page 27).
•
The conversation timer is about to expire (page 28).
•
The system received your page but the paged mobile is not on the air
(page 42).
•
Telephone interconnect is not operational (page 39).
Continuous Tone (Invalid or No Acknowledge Condition)
•
A transmission is being attempted on an unprogrammed channel or a
conventional channel programmed as receive-only.
•
The transmitter is disabled by the busy channel lockout feature
(page 26).
•
The transmitter has been disabled by the time-out timer feature
(page 17).
•
The transmitter has been disabled by the conversation timer (page 28).
•
An out-of-range condition exists (SMARTNET/SmartZone only).
•
A transmission is being attempted before the penalty timer has expired
(page 27).
•
Dynamic regrouping has been exited but the dynamic regrouping
channel is still selected (page 46).