INTRODUCTION AND OPERATION
1-9
August 2000
Part No. 001-2001-200
SPECIFICATIONS
GENERAL (Per TIA 603)
1
Frequency Ranges
132-178 MHz Transmit/Receive (132-150 MHz and 150-178 MHz)
Dimensions
9.125" H x 17" W x 20.9" D
AC Voltage/Frequency
100-240V AC/50-60 Hz
AC Current
0.38A (Standby), 1.4A (25W), 5A (110W)
AC Input Power
45W (Standby), 170W (25W), 560W (110W)
DC Current at 26.5V DC (Low Power) 6.3A (25W), 16.5A (110W)
Number of Channels
1 (Synthesized, programmable)
Channel Spacing
12.5 /15 /25 /30 kHz selectable
Channel Resolution
5 / 6.25 kHz
Temperature Range
-30
°
C to +60
°
C (-22
°
F to +140
°
F)
Duty Cycle
Continuous
FCC Type Acceptance
ATH2422001
FCC Compliance
Parts 15, 90
RECEIVER (Per TIA 603)
12 dB SINAD
0.35
µ
V
20 dB Quieting
0.50
µ
V
Signal Displacement Bandwidth
±
1 kHz (12.5/15 kHz), ±2.0 kHz (25/30 kHz)
Adjacent Channel Rejection
-85 dB (12.5/15 kHz), -90 dB (25/30 kHz)
Intermodulation Rejection
-85 dB
Spurious & Image Rejection
-100 dB
Audio Squelch Sensitivity
12 dB SINAD
Audio Response
+1/-3 dB TIA
Audio Distortion
Less than 3% at 0.5W/16 ohms
Local Audio Power
0.5W/16 ohms
Audio Sensitivity
±0.75 kHz (12.5/15 kHz),
±
1.5 kHz (25/30 kHz)
Hum & Noise Ratio
-50 dB
Frequency Spread
2 MHz
Frequency Stability
±
2.5 PPM -30
°
C to +60
°
C (-22
°
F to +140
°
F)
Modulation Acceptance Bandwidth
±3.5 kHz (12.5/15 kHz), ±7.0 kHz (25/30 kHz)
TRANSMITTER (Per TIA 603)
RF Power Out
132-178 MHz 110W (Default setting), 25-110W (Variable Set Point)
Spurious Emissions
-90 dBc
Harmonic Emissions
-90 dBc
Audio Deviation
±1.6 kHz (12.5/15 kHz),
±
3.5 kHz (25/30 kHz)
LTR Data Deviation
±0.8 kHz (12.5/15 kHz),
±
1 kHz (25/30 kHz)
CWID Deviation
±1 kHz (12.5/15 kHz),
±
2 kHz (25/30 kHz)
Repeat Deviation
±0.8 kHz (12.5/15 kHz),
±
1.5 kHz (25/30 kHz)
Audio Response
+1/-3 dB TIA
Audio Distortion
Less than 2%
Hum & Noise (TIA)
-50 dB (12.5/15 kHz), -55 dB (25/30 kHz)
Frequency Spread
6 MHz
Frequency Stability
±
2.5 PPM -30
°
C to +60
°
C (-22
°
F to +140
°
F)
Emission Designators
11K0F3E, 16K0F3E
These general specifications are intended for reference and are subject to change without notice.
Contact the Systems Applications consultants for guaranteed or additional specifications.
Summary of Contents for 242-20X1-213
Page 2: ...1 2 October 1995 Part No 001 2008 202 ...
Page 14: ...TABLE OF CONTENTS CONT 10 ...
Page 24: ...INTRODUCTION AND OPERATION 1 10 August 2000 Part No 001 2001 200 ...
Page 94: ...CIRCUIT DESCRIPTION 6 44 August 2000 Part No 001 2001 200 ...
Page 118: ...ALIGNMENT AND TEST PROCEDURES 7 20 August 2000 Part No 001 2001 200 ...
Page 126: ...SERVICING 8 8 August 2000 Part No 001 2001 200 ...
Page 160: ...PARTS LIST 9 34 August 2000 Part No 001 2001 200 ...
Page 197: ......
Page 198: ...Part Number 001 2001 200 8 00mwp Printed in U S A ...