11  Ordering Guide

EE310

Hardware Configuration

Approval

without

no code

UL-Approval

AP1

Type

wall mounting

T1

duct mounting

T2

remote probe up to 180 °C (356 °F)

T5

remote probe up to 180 °C (356 °F) and 100 bar (1435 psi)

T8

remote probe up to 180 °C (356 °F)and 20 bar (300 psi)

T10

Filter

plastic - PTFE membrane (up to 180 °C / 356 °F)

F2

plastic - metal grid (up to 120 °C / 248 °F)

F3

stainless steel sintered

no code

PTFE

F5

stainless steel - metal grid (up to 180 °C / 356 °F)

F9

H

2

O

F12

oil

F13

oil (short)

F16

Cable length

(incl. probe length)

0.5 m (1.64 ft)

K0.5

K0.5

K0.5

1 m (3.3 ft)

K1

K1

K1

2 m (6.6 ft)

no code

no code

no code

5 m (16.4 ft)

K5

K5

K5

10 m (32.8 ft)

K10

K10

K10

20 m (65.6 ft)

K20

K20

K20

Probe length

50 mm (2“)

L50

L50

65 mm (2.55“)

L65

L65

L65

100 mm (3.9“)

L100

L100

L100

L100

200 mm (7.9“)

no code

no code

no code

no code

300 mm (11.7“)

L300

L300

L300

L300

400 mm (15.8“)

L400

L400

L400

L400

600 mm (23.6“)

L600

L600

L600

L600

800 mm (31.5“)

L800

L800

L800

L800

1000 mm (39.4“)

L1000

L1000

L1000

L1000

Process connection

without probe fitting

no code

1/2“ ISO - cut in fitting; 12 mm (0.47“)

PA20

PA20

1/2“ weld - cut in fitting; 12 mm (0.47“)

PA21

PA21

1/2“ NPT - cut in fitting; 12 mm (0.47“)

PA22

PA22

1/2“ ISO - cut in fitting; 13 mm (0.51“)

PA23

1/2“ weld - cut in fitting; 13 mm (0.51“)

PA24

1/2“ NPT - cut in fitting; 13 mm (0.51“)

PA25

Electrical connection

1)

cable glands

no code

1 plug for power supply and outputs

E4

1 cable gland / 1 plug for Modbus RTU

E5

2 plugs for power supply / outputs and for Modbus RTU

E6

3 plugs for power supply / outputs and Modbus RTU 

8)

E12

conduit fitting

E23

liquid-tight 1/2“ conduit fitting

E24

Optional features

TFT colour display with integrated data logger 

2)

D2

Modbus RTU

J3

E+E sensor coating

C1

alarm outputs 

3) 4)

AM2

alarm outputs 

4) 6)

 

liquid-tight 1/2“ conduit fitting

AM6

integrated power supply 100...240 V AC, 50/60 Hz 

4) 5)

AM3

integrated power supply 100...240 V AC, 50/60 Hz 

4) 7)

liquid-tight 1/2“ conduit fitting

AM5

Setup - 

Analogue outputs

Output 1

relative humidity RH

[%]

no code

other measurand

(

xx

 see Measurand Code below)

MA

xx

Output Signal 1

0-1 V

GA1

0-5 V

GA2

0-10 V

GA3

0-20 mA

GA5

4-20 mA

GA6

Scaling 1 low 

0

no code

value

SAL

value

Scaling 1 high

100

no code

value

SAH

value

Output 2

temperature T

[°C]

no code

temperature T

[°F]

MB2

other measurand

(

xx

 see Measurand Code below)

MB

xx

Output Signal 2

0-1 V

GB1

0-5 V

GB2

0-10 V

GB3

0-20 mA

GB5

4-20 mA

GB6

Scaling 2 low

value

SBL

value

Scaling 2 high

value

SBH

value

1) Plug options E5 / E6 / E12 only in combination with Modbus RTU option J3.

2)  Factory setup: the display shows the measurands selected for output 1 and output 2 

Default language English, other languages selectable in display menu.

3) Alarm output with cable glands

4)   Combination of alarm output and integrated power supply is not possible

5)  Integrated power supply includes 2 plugs for power supply and outputs

6) Alarm output with two 1/2” liguid-tight conduit fittings

7) Integrated power supply with two 1/2” liquid-tight conduit fittings

11.1  Measurand Code

MAxx / MBxx

relative humidity

%

10

Temperature

°C

1

°F

2

dew point Td

°C

52

°F

53

frost point Tf

°C

65

°F

66

mixing ratio r

g/kg

60

gr/lb

61

MAxx / MBxx

absolute humidity dv

g/m³

56

gr/ft³

57

wet bulb temperature Tw

°C

54

°F

55

water vapour partial pressure e

mbar

50

psi

51

specific enthalpy h

kJ/kg

62

BTU/lb

64

Summary of Contents for EE310

Page 1: ...BA_EE310_UL V1 0 Technical data subject to change 194720 Operation manual EE310 Humidity Temperature Transmitter...

Page 2: ...imits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequenc...

Page 3: ...to 180 C 356 F 20 3 3 4 T10 T8 Remote probe up to 180 C 356 F 21 3 3 5 T10 Installation of the probe directly in the process with sliding fitting up to 20 bar 290 psi 22 3 3 6 T10 Installation of the...

Page 4: ...d The replacement of the filter cap shall be done with utmost care not to touch the sensors Installation electrical connection maintenance and commissioning shall be performed by qualified staff only...

Page 5: ...four measurands simultaneously and offers exten sive error diagnostics The integrated data logging function saves all measured and calculated values to the internal memory The data can be displayed as...

Page 6: ...dels EE310 is available for wall surface or duct mount as well as with various remote probes The remote probes can be employed up to 180 C 356 F and 20 bar 300 psi T1 Wall or surface mounting T2 Duct...

Page 7: ...4 09 71 2 80 5 1 0 20 166 6 54 180 7 09 153 6 02 54 2 13 14 0 55 166 6 54 5 1 0 20 7 0 28 Fig 4 Dimensions and mounting template of polycarbonate enclosure in mm inch The four housing screws shall be...

Page 8: ...on according to NAMUR NE43 In the case of an error the output signal will freeze at 21 mA or 11 V respectively Note By default the error indication is disabled When changing one of the analogue output...

Page 9: ...c 50 60Hz Class 2 supply 8 35Vdc LPS V 1 GND 2 Outputs Model Type Ratings Terminals EE310 Out 1 0 1V 0 5V 0 10V 0 20mA 4 20mA SELV Limited Energy source Out 1 4 GND 3 Out 2 0 1V 0 5V 0 10V 0 20mA 4 20...

Page 10: ...A D n c n c 2 1 4 3 5 RS485 B D GND RS485 shielded RS485 A D n c Modbus RTU n c Fig 8 Plug option E4 for EE310 front connector view Model Supply Input Terminals Voltage Frequency EE310 with option E4...

Page 11: ...J3 Modbus RTU 0 5V SELV Limited Energy source RS485 A D 2 RS485 B D 4 GND RS485 5 Tab 4 M12 connector Modbus RTU 3 2 4 Connection diagram Options E6 and E12 power supply analogue output 1 2 3 4 5 GND...

Page 12: ...5 B D 4 GND RS485 5 Tab 6 M12 connector Modbus RTU 1 and or 2 3 2 5 Connection diagram Conduit option Conduit option electrical connection on terminal block in bottom housing part Conduit fitting opti...

Page 13: ...rminals Voltage Frequency EE310 Indoor use 12 to 30Vac 50 60Hz Class 2 supply 8 35Vdc LPS Outdoor use 12 to 16Vac 50 60Hz Class 2 supply 8 35Vdc LPS V 1 GND 2 Outputs Model Type Ratings Terminals EE31...

Page 14: ...c Power supply 100 240 V AC for polycarbonate enclosure 2 1 4 3 5 RS485 B D GND RS485 shielded RS485 A D n c Modbus RTU n c Fig 12 Plug option AM3 for EE310 front connector view External diameter of...

Page 15: ...nalogue and digital output 3 2 7 Connection digram for integrated power supply module AM5 Wire size 30 16AWG Type CU Terminal torque USA 7 Lb In CANADA 0 8 Nm Fig 13 Option AM5 with liquid tight condu...

Page 16: ...ND RS485 5 Tab 9 Electrical connection for integrated power supply module AM5 3 2 8 Connection diagram for alarm outputs AM2 For indoor use surface mounted according NFPA 79 applications only NO NC C...

Page 17: ...A 0 7 Nm Model Supply Input Terminals Voltage Frequency EE310 with option AM2 12 to 30Vac 50 60Hz Class 2 supply 8 35Vdc LPS V 1 GND 2 Outputs Model Type Ratings Terminals EE310 with option AM2 Out 1...

Page 18: ...ply Input Terminals Voltage Frequency EE310 with option AM6 Relay 1 Max switch load 250 Vac 6 A and 28 Vdc 6 A Min switch load 12 Vacdc 100 mA C 5 NO 4 C 5 NC 6 EE310 with option AM6 Relay 2 Max switc...

Page 19: ...r surface mount transmitters For mounting template of enclosure see chapter 3 1 Mechanical installation Fig 4 Dimensions and mounting template of polycarbonate enclosure in mm inch T working range 40...

Page 20: ...mounting flange see chapter 8 Replacement parts Accessories The immersion depth is adjustable The probe shall be horizontal In case of mounting into a separation wall it is of paramount importance for...

Page 21: ...paramount importance to avoid T gradients along the probe In case of large T difference between the front and the back of the probe it is highly recommended to insert the probe completely into the pro...

Page 22: ...ring probe installa tion may deviate by max 40 C 72 F from the regular temperature during normal operation Replace the metal sealing ring see Fig 19 Installation of the EE310 probe directly into the p...

Page 23: ...force of the clamping sleeve This leads the risk of sudden expulsion of the sensing probe due to the pressure A torque higher than 30 Nm may lead to permanent deformation of the clamping sleeve and t...

Page 24: ...l pipe threads Never rotate the screw connection body Instead hold the screw connection body securely and turn the union nut Avoid unnecessary disassembly of unused pipe screw connections Installation...

Page 25: ...RELAY 2 RELAY 1 AM2 AM6 Fig 23 Alarm module option AM2 AM6 AM6 In accordance with NFPA 70 NEC and with CSA C22 1 CEC Part 1 A switch or circuit breaker must be included in the installation It must be...

Page 26: ...itching point Switching point Hysteresis Standard Inverted Normal state Switch window Measurand Switching point low Switching point Hysteresis Switching point high Switching point Hysteresis Standard...

Page 27: ...National regulations for installation must be observed AM5 In accordance with NFPA 70 NEC and with CSA C22 1 CEC Part 1 A switch or circuit breaker must be included in the installation It must be mark...

Page 28: ...int temperature C 32 bit float 31107 452 Dew point temperature F 32 bit float 31131 46A Frost point Dew point temperature C 32 bit float 31133 46C Frost point Dew point temperature F 32 bit float 3111...

Page 29: ...er the USB cable is connected the transmitter is initialised and the configuration is loaded The green status LED flashes and indicates proper operation of the electronics Blind cover USB cable Fig 29...

Page 30: ...ith push buttons 5 3 Chart Data logger The TFT display with the integrated data logging function saves all measured and calculated values to the internal memory The data logger has a real time clock U...

Page 31: ...ter content ppm Wet bulb temp K Dew point K Frost point K Volume concentr ppm Scale minimum Scale maximum 1 Home button 2 Configuration incl data logger menu 3 Time scale for the graph 5 min 3 months...

Page 32: ...on relay configuration mode set points state adjustment 1 and 2 point humidity temperature adjustment reset to factory adjustment calibration status configuration of Modbus RTU data transmission Devic...

Page 33: ...le with 0 1 V output Tab 10 Overview of error codes Error category 1 non critical error can be solved by the user The display blinks and the buzzer beeps every 10 seconds The red status LED lights con...

Page 34: ...opriate filter type Contact E E representative for advice High humidity values red LED blinks Water in sensing head Investigate the cause for water condensation Contact E E representative for advice I...

Page 35: ...er Depending on the level of accuracy required the humidity reference can be Humidity Calibrator e g Humor 20 please see www epluse com humor20 Handheld device e g Omniport30 please see www epluse com...

Page 36: ...3 1 all versions Mating plug for integrated power supply AM3 Mating plug RKC 5 7 AM3 E4 E6 E12 Mating plug RSC 5 7 2 pcs for option E12 E5 E6 E12 Other languages can be downloaded at www epluse com EE...

Page 37: ...ncluding 2 voltage or current outputs display and relay option AM2 or AM6 AM3 and AM5 option max 5 VA Including 2 voltage or current outputs and display option Pressure range for pressure tight probe...

Page 38: ...asurands brightness display alarm output configuration mode measurands scaling error indication relay configuration mode set points state adjustment 1 and 2 point humidity temperature adjustment reset...

Page 39: ...TU lb Frost point C Frost point F Water activity aw Saturation Water content ppm Wet bulb temp K Dew point K Frost point K Volume concentr ppm Layout Display settings Measurand 2 Measurand 1 Measurand...

Page 40: ...C Wet bulb temp F Abs humidity g m Abs humidity gr ft Mixing ratio g kg Mixing ratio gr lb Enthalpy kJ kg Enthalpy ft lbf lb Enthalpy BTU lb Frost point C Frost point F Water activity aw Saturation Wa...

Page 41: ...ing system Working pressure Probe replacement Parameters Humidity coefficient Resistance R0 Capacity C76 Capacity gain Capacity offset Temperature coefficient TK Resistance Offset Code Daylight saving...

Page 42: ...steresis Standard Inverted Normal state Error indication Standard Inverted Normal state OFF Temperature C Temperature F Temperature K Rel humidity Vap p pressure mbar Vap p pressure psi Dew point C De...

Page 43: ...Modbus RTU 8 E12 conduit fitting E23 liquid tight 1 2 conduit fitting E24 Optional features TFT colour display with integrated data logger 2 D2 Modbus RTU J3 E E sensor coating C1 alarm outputs 3 4 A...

Page 44: ...w epluse cn BEIJING Tel 86 10 84992361 info epluse cn SHANGHAI Tel 86 21 61176129 info epluse cn E E GERMANY www epluse de Tel 49 6172 13881 0 info epluse de E E FRANCE www epluse fr Tel 33 4 7472 35...

Reviews: