Operating instructions for EE310 Humidity / Temperature Transmitter
11 Ordering Guide
EE310
Hardware Configuration
Approval
without
no code
UL-Approval
AP1
Type
wall mounting
T1
duct mounting
T2
remote probe up to 180 °C (356 °F)
T5
remote probe up to 180 °C (356 °F) and 100 bar (1435 psi)
T8
remote probe up to 180 °C (356 °F)and 20 bar (300 psi)
T10
Filter
plastic - PTFE membrane (up to 180 °C / 356 °F)
F2
plastic - metal grid (up to 120 °C / 248 °F)
F3
stainless steel sintered
no code
PTFE
F5
stainless steel - metal grid (up to 180 °C / 356 °F)
F9
H
2
O
2
F12
oil
F13
oil (short)
F16
Cable length
(incl. probe length)
0.5 m (1.64 ft)
K0.5
K0.5
K0.5
1 m (3.3 ft)
K1
K1
K1
2 m (6.6 ft)
no code
no code
no code
5 m (16.4 ft)
K5
K5
K5
10 m (32.8 ft)
K10
K10
K10
20 m (65.6 ft)
K20
K20
K20
Probe length
50 mm (2“)
L50
L50
65 mm (2.55“)
L65
L65
L65
100 mm (3.9“)
L100
L100
L100
L100
200 mm (7.9“)
no code
no code
no code
no code
300 mm (11.7“)
L300
L300
L300
L300
400 mm (15.8“)
L400
L400
L400
L400
600 mm (23.6“)
L600
L600
L600
L600
800 mm (31.5“)
L800
L800
L800
L800
1000 mm (39.4“)
L1000
L1000
L1000
L1000
Process connection
without probe fitting
no code
1/2“ ISO - cut in fitting; 12 mm (0.47“)
PA20
PA20
1/2“ weld - cut in fitting; 12 mm (0.47“)
PA21
PA21
1/2“ NPT - cut in fitting; 12 mm (0.47“)
PA22
PA22
1/2“ ISO - cut in fitting; 13 mm (0.51“)
PA23
1/2“ weld - cut in fitting; 13 mm (0.51“)
PA24
1/2“ NPT - cut in fitting; 13 mm (0.51“)
PA25
Electrical connection
1)
cable glands
no code
1 plug for power supply and outputs
E4
1 cable gland / 1 plug for Modbus RTU
E5
2 plugs for power supply / outputs and for Modbus RTU
E6
3 plugs for power supply / outputs and Modbus RTU
8)
E12
conduit fitting
E23
liquid-tight 1/2“ conduit fitting
E24
Optional features
TFT colour display with integrated data logger
2)
D2
Modbus RTU
J3
E+E sensor coating
C1
alarm outputs
3) 4)
AM2
alarm outputs
4) 6)
liquid-tight 1/2“ conduit fitting
AM6
integrated power supply 100...240 V AC, 50/60 Hz
4) 5)
AM3
integrated power supply 100...240 V AC, 50/60 Hz
4) 7)
liquid-tight 1/2“ conduit fitting
AM5
Setup -
Analogue outputs
Output 1
relative humidity RH
[%]
no code
other measurand
(
xx
see Measurand Code below)
MA
xx
Output Signal 1
0-1 V
GA1
0-5 V
GA2
0-10 V
GA3
0-20 mA
GA5
4-20 mA
GA6
Scaling 1 low
0
no code
value
SAL
value
Scaling 1 high
100
no code
value
SAH
value
Output 2
temperature T
[°C]
no code
temperature T
[°F]
MB2
other measurand
(
xx
see Measurand Code below)
MB
xx
Output Signal 2
0-1 V
GB1
0-5 V
GB2
0-10 V
GB3
0-20 mA
GB5
4-20 mA
GB6
Scaling 2 low
value
SBL
value
Scaling 2 high
value
SBH
value
1) Plug options E5 / E6 / E12 only in combination with Modbus RTU option J3.
2) Factory setup: the display shows the measurands selected for output 1 and output 2
Default language English, other languages selectable in display menu.
3) Alarm output with cable glands
4) Combination of alarm output and integrated power supply is not possible
5) Integrated power supply includes 2 plugs for power supply and outputs
6) Alarm output with two 1/2” liguid-tight conduit fittings
7) Integrated power supply with two 1/2” liquid-tight conduit fittings
11.1 Measurand Code
MAxx / MBxx
relative humidity
%
10
Temperature
°C
1
°F
2
dew point Td
°C
52
°F
53
frost point Tf
°C
65
°F
66
mixing ratio r
g/kg
60
gr/lb
61
MAxx / MBxx
absolute humidity dv
g/m³
56
gr/ft³
57
wet bulb temperature Tw
°C
54
°F
55
water vapour partial pressure e
mbar
50
psi
51
specific enthalpy h
kJ/kg
62
BTU/lb
64