PRODUCT INSPECTION PROCEDURE
Disclaimer:
The information in this document is confidential. It may not be reproduced in whole, or in
part, nor may any of the information contained therein be disclosed without the prior consent of e-con
Systems India Pvt Ltd
Format # : EDSG/F/015
Rev# : 1.1
4
STROBE
Output (PD) Strobe output from camera
sensor
5
NC
-
-
-
6
NC
-
-
-
7
NC
-
-
-
8
TRIG
Input (PD) External trigger signal to
Camera Sensor
Connect to Ground through push
button switch with necessary de-
bouncing circuitry.
9
NC
-
-
-
10
GROUND
Power
Device power ground
-
8. Impedance/Sanity check points
S. No
Voltage
Source
Test
Component
Voltage reading ( ±10% Tolerance
)
1
C88
1.8V
2
C78
3.3V
3
C86
1.2V
4
C85
2.7V
5
C83
1.2V
6
C47
5V
Voltage short continuity test should be checked on the above-mentioned test component with respect
to ground.
9. Connection Setup, Test Procedure and Acceptance
criteria
The section describes the test preparation in Diagcam application. Define the following parameters for
each camera. These are the accessories to be used for the diagnostic testing.
Product Name
See3CAM_130A
Product Code
See3CAM_130A
Firmware version
1.2.131.1443
Test PC
PC with USB host.
OS
Windows 8.1 or 10.
DiagCam version
1.0.32 or above.
Lens
Auto focus