PRODUCT INSPECTION PROCEDURE
Disclaimer:
The information in this document is confidential. It may not be reproduced in whole, or in
part, nor may any of the information contained therein be disclosed without the prior consent of e-con
Systems India Pvt Ltd
Format # : EDSG/F/015
Rev# : 1.1
•
On default exposure, the image of a color chart should look similar to the reference image
available below,
Reference Image - See3CAM_130_ReferenceImage_Quality.bmp
https://www.dropbox.com/s/228beoiwjx6x5wg/See3CAM_130_Production_Refer-
enceImages.zip?dl=0&file_subpath=%2FSee3CAM_130_Production_Refer-
enceImages%2FSee3CAM_130_ReferenceImage_Quality.bmp
•
On increasing the exposure to maximum and point the camera towards light source until the
frame becomes full white. The image should be saturated completely (all the pixels are white).
There should not be any part which is not completely white.
Reference Image - See3CAM_130_ReferenceImage_Saturation.bmp
https://www.dropbox.com/s/228beoiwjx6x5wg/See3CAM_130_Production_Refer-
enceImages.zip?dl=0&file_subpath=%2FSee3CAM_130_Production_Refer-
enceImages%2FSee3CAM_130_ReferenceImage_Saturation.bmp
•
On decreasing the exposure to minimum, the image should be saturated completely (all the
pixels are black). There should not be any part which is not completely white. The image should
be completely black. There should not be any hot pixels.
Reference Image - See3CAM_130_ReferenceImage_Black.bmp
https://www.dropbox.com/s/228beoiwjx6x5wg/See3CAM_130_Production_Refer-
enceImages.zip?dl=0&file_subpath=%2FSee3CAM_130_Production_Refer-
enceImages%2FSee3CAM_130_ReferenceImage_Black.bmp
•
Remove the camera, connect the next one and press the “Disconnect & Continue” button and
perform the tests for next camera.
•
User shall be prompted to disconnect the camera, if the camera is not disconnected.