Dismounting/ Mounting condensate trap and
condensate trap hose:
Remove 2 hoses on condensate trap.
Remove 2 screws on the lower chassis for complete
Dismounting of condensate trap.
Remove 2 screws on the lower chassis for complete
Dismounting of condensate trap.
Mounting/ dismounting motorized valve:
Remove the motorized valve by unlatching the clip
holding the manifold and the motorized valve.
Unscrew
the screw on the valve motor in order to
replace the cable of the motorized valve. Remove the
notch of cable from its hold using a hand tool.
Dismounting/ mounting water pressure sensor:
It is necessary firstly to dismount the condensate trap
completely in order to dismounting water pressure
sensor. Afterward, remove the water pressure sensor
cable.