5.1.4.
PLUME KIT ASSEMBLY
For Plume kit installation, follow the instructions in the
image below, you must disassemble the
part
at the end of
the horizontal flue kit (7006991167) and assemble with the
Plume kit (700991251).
Do not disassemble this part
"A"
in
case of single horizontal flue kit
usage.
A
Figure
7
.
Plume Kıt
5
.
1
.
3.
Plume Management Kit
Standard plume management kit lenght is 1m. It is
an accessory and part code is 7006991251. The
minimum distance between nearest window and air inlet
side of the flue must be bigger than 150 mm.
Figure
6
. Plume Management Kit
Plume
Management
Kit
6
- INSTALLATION
6
.1
.
Selection of Location of Boiler
The boiler must be installed in accordance with gas
safety regulations and relevant standards.
Additionally, the clearance around the boiler should be
as shown in fig
1
2
. In order to make service,
maintenance and usage easier.
Figure 1
2
: It shows the minimum distances required from
the top and sides of the boiler (Dimensions given
in mm).
The installation must comply with the following minimum
distances so that servicing and maintenance of the boiler
can be performed correctly. The position of the boiler
must be checked against technical requirements.
Figure
8
.Combi Mounting
Clearances
CAUTIONS :
Do not install your boilers in locations
that will be exposed to direct sunlight.
Sunlight can
cause color change on the
exterior of your boiler over time.
Ambient temperature of boiler's
installation location should be between
5 -35
0
C.
The boiler can be used at altitudes
up to 2000 m above sea level.
There is no need to remove side
panels in the combi boiler service
operations.
Minimum
50 mm
clearances are given taking into
consideration the share of possible
side panel
sheet changes.
1
Figure
9
.
Isolation Valve
Cover Mounting
Since the outside temperature of the boiler
does not
rise above 85° C at the maximum heating power, no
special protective measures are required against the
combustible construction materials and components.
12