35
COMMISSIONING
7
7
7
7
7.1
.1
.1
.1
.1
IIIII
NS
NS
NS
NS
NST
TT
TTALLA
ALLA
ALLA
ALLA
ALLATION
TION
TION
TION
TION
AND
AND
AND
AND
AND
M
M
M
M
M
OUNTING
OUNTING
OUNTING
OUNTING
OUNTING
Please read the entire manual prior to installation and use.
•
Do not remove protective cap until ready to install.
•
Prior to initial installation, verify correct machining of mounting hole.
•
When reinstalling, make sure mounting hole is clear of frozen plastic.
•
Transducer should be removed when at operating temperature (no pressure in system).
7.1.1
7.1.1
7.1.1
7.1.1
7.1.1
A
A
A
A
A
H
H
H
H
H
AZARDOUS
AZARDOUS
AZARDOUS
AZARDOUS
AZARDOUS
A
A
A
A
A
REA
REA
REA
REA
REA
I
I
I
I
I
NS
NS
NS
NS
NST
TT
TTALLA
ALLA
ALLA
ALLA
ALLATIONS
TIONS
TIONS
TIONS
TIONS
Dynisco’s IPX II Series of Smart Pressure Transmitters are designed with circuitry suitable for
operation in a Class I , Division 1, Groups B, C & D, Class I/II, Division 2, Groups E, F & G
hazardous area. An explosion-proof electronics housing is standard on all IPX II Series models. The
specific approvals carried by individual transmitters are marked on the label. Refer to the product
data sheet for the most current information on these approvals.
7.1.1
7.1.1
7.1.1
7.1.1
7.1.1
B
B
B
B
B
IIIII
NTRINSICALL
NTRINSICALL
NTRINSICALL
NTRINSICALL
NTRINSICALLY
Y
Y
Y
Y
S
S
S
S
S
AFE
AFE
AFE
AFE
AFE
I
I
I
I
I
NS
NS
NS
NS
NST
TT
TTALLA
ALLA
ALLA
ALLA
ALLATIONS
TIONS
TIONS
TIONS
TIONS
Dynisco’s IPX II Series of Smart Pressure Transmitters are designed with circuitry suitable for
operation in Intrinsically safe environments, with an approval code of EEx ia IIC T4.
The customer is required to install an approved galvanic barrier with entity parameters from Drawing
The customer is required to install an approved galvanic barrier with entity parameters from Drawing
The customer is required to install an approved galvanic barrier with entity parameters from Drawing
The customer is required to install an approved galvanic barrier with entity parameters from Drawing
The customer is required to install an approved galvanic barrier with entity parameters from Drawing
000092.
000092.
000092.
000092.
000092.
The specific approvals carried by individual transmitters are marked on the label. Refer to the product
data sheet for the most current information on these approvals.
Each sensor cable supplied with a cap plug (Dynisco P/N 598091) to protect the Bendix
connector from environmental conditions. Do not remove cap plug until you are ready to
connect to the sensor assembly.
Summary of Contents for IPX II Series
Page 2: ...OPERATING MANUAL...
Page 74: ...74 EX DECLARATION...
Page 75: ...75 EX DECLARATION...
Page 76: ...76 EX DECLARATION...
Page 77: ......