Before mounting the PT, ensure that the mounting hole is free from plastic residue. Remove
plastic residue with the D
D
D
D
DYNISC
YNISC
YNISC
YNISC
YNISCO
O
O
O
O cleaning tool kit. A test bolt is included with this cleaning
set.
To prevent the PT from sticking permanently in the mounting hole, coat the thread section of
the transmitter with high temperature resistant grease or a suitable parting agent.
•
Check the mounting hole with the test bolt, and clean with cleaning set if necessary.
•
Coat the thread section of the transmitter with high temperature resistant grease or a suitable
parting agent.
Always use a spanner applied to the designated hexagon collar when screwing the PT in
and out. Do not apply the tool to the housing or housing / sensor connection!
Maximum mounting torque 500 inch-pounds. If the mounting torque is too high, the PT
may be damaged or its zero point may shift.
•
Screw the PT into the mounting hole and tighten.
6.4
6.4
6.4
6.4
6.4
M
M
M
M
M
OUNTING
OUNTING
OUNTING
OUNTING
OUNTING
P
P
P
P
PT
TT
TT
S
S
S
S
S
WITH
WITH
WITH
WITH
WITH
F
F
F
F
F
LEXIBLE
LEXIBLE
LEXIBLE
LEXIBLE
LEXIBLE
S
S
S
S
S
TEM
TEM
TEM
TEM
TEM
Mounting a PT with a flexible stem to the pressure sensor is done analogously to the procedure in
6.3.
Avoid kinking or crushing the flexible stem.
Minimum bending radius
•
1” (25 mm)
1” (25 mm)
1” (25 mm)
1” (25 mm)
1” (25 mm) for protected capillary
The connector must be easily accessible (on connector versions).
•
Mount the electronics housing of the PT with the fastening clip. See mounting example in figure
6-6.
•
Additionally secure the flexible stem between the electronics housing with a standard cable clip.