29
Dynaset Oy | Menotie 3, 33470 Ylöjärvi | puh. 03 3488 200 | [email protected] | www.dynaset.com
HYDRAULIC MAGNETS
MAINTENANCE
6. MAINTENANCE
6.1. MAINTENANCE INTERVALS
All maintenance must be performed as they are scheduled in this manual. The
following table provides maintenance schedule for DYNASET HMAG PRO.
CHECK POINTS
DAILY
Check if the HMAG PRO’s generator needs cleaning and clean
it according to the chapter 6.4.
x
Check the condition of the chains before starting the work
with HMAG PRO.
x
6.2. HYDRAULIC FLUIDS
A wide range of standard hydraulic fluids can be used with the DYNASET hydraulic
equipment. Depending on the operating temperature, the following mineral
hydraulic oils are recommended:
MINERAL HYDRAULIC OIL
OPERATION TEMPERATURE UP TO
ISO VG 32S
60 °C
ISO VG 46S
70 °C
ISO VG 68S
80 °C
NOTE!
Recommended oil viscosity is between 10 to 35 cSt when operating at
normal operating temperature.
Synthetic and bio-oils can also be used if their viscosity characteristics and
lubricating efficiency are similar to the mineral oils.
Automatic transmission fluids and even engine oils can be used, provided that
they are allowed to be used in hydraulic system of your base machine.
For the hydraulic fluid change interval follow the base machine’s maintenance
instructions.
To use special hydraulic fluids with DYNASET equipment, please contact the
nearest DYNASET representative for more information.