Valve operation is tracked and
real-time status of relative distribution
is provided on the LCD display.
1:
1
3
2
4
5
OK 000
2:
3:
4:
26%
24%
25%
25%
6404 – Outlet 3 active, status OK
6605 – Outlet 5 active, status ALARM
1:
1
4
2
3
5
ERR 008
2:
3:
4:
5:
17%
27%
16%
17%
33%
IntellIgent ValVe MonItor™
IVM6000™-lP line Powered Version
for reliable designs and peace of mind
TM
Works with all third party 6000 series distributing valves
Alarm Event
Description / Explanation
Percent Deviation
Exceeded
Uneven distribution has occurred.
Inlet No Outlet
RDSA is not fully seating in “down”
position. Water is flowing out of all
outlets at the same time.
Outlet No Inlet
RDSA may not be returning to
the fully “up” position. Check for
broken stem spring or debris.
Outlet is Stuck
Valve does not cycle to next
outlet.
Cam Mismatch
Incorrect or damaged valve
cam.
Out of Sequence
Outlets were not activated in
correct order.
Outlet on Too
Long
Maximum pump dose time
pre-set value exceeded.
Outlet off Too
Early
Minimum pump dose time
pre-set value not met.
Temperature
Alarm
Below minimum or exceeded
maximum temperature value.
Device Reset
Possible power failure
IVM-2012-SS-04
U.S. Patent No. 7,735,509. Canadian Patent Pending
Dynamic Monitors is a developer of innovative electronic monitoring devices for the environmental sector and is not affiliated with K-Rain Corporation of West Palm Beach, FL.
toll free 1-888-747-7645
Direct 1-902-628-1705
Product Specifications
Valve/Cam Model:
All 6000 series. 2, 3, 4, 5 or 6 outlets.
Line power:
Any from 6V ~ 30V AC or DC.
Use standard 24V AC (40VA)
transformer
Power consumption:
<50mA @ 24V AC, <1.2Watts max
Alarm output:
Relay contact ratings 1A/30V DC
max, 0.5A/125V AC max.
Event Storage:
Records all events with 255+
repeat counts on each entry.
Dimensions:
9.5” x 8.5” x 7.5” (high)
(240mm x 216mm x 191mm)
Shipping Dimensions:
10” x 10” x 10” box
Cable:
24 AWG 4/8 Conductor, Direct bury,
10 ft (3.0m) standard
Weight:
approx. 2 lbs 15 oz (1325g)
Materials:
Case ABS, Lens: Polycarbonate
Measurement resolution:
1 second
Operating Temperature:
-20°C to 50°C (-4°F to 122°F)
Storage Temperature:
-40°C to 80°C (-40°F to 176°F)
Other user adjustable parameters:
• Allowable outlet percent variation
• Valve model/cam
• Alarm error sensitivity (Low, Medium, High)
• Minimum, maximum (pump dose) on time
• Minimum, maximum alarm temperatures
• Date and time
• Lifetime and resettable counters/timers
• LCD backlight
Installation:
Slides down over top of valve.
Replace original rubber disk
and stem assembly (RDSA)
with sensor-enabled RDSA
supplied with monitor.
IVM RDSA
(dark blue stem)