Quick Start Guide

IVM6000

TM

- LP

Intelligent Valve Monitor

TM

Line Powered Version

 

Direct: 902-628-1705

Toll Free: 1-888-747-7645

[email protected]

Copyright  ©

 2020 

by Dynamic Monitors

US Patent No. 7735509, 8397744, 

Canadian Patent No. 

2506309

October 2020

Summary of Contents for IVM6000-LP

Page 1: ...TM LP Intelligent Valve MonitorTM Line Powered Version Direct 902 628 1705 Toll Free 1 888 747 7645 IVM DynamicMonitors com Copyright 2020 by Dynamic Monitors US Patent No 7735509 8397744 Canadian Patent No 2506309 October 2020 ...

Page 2: ......

Page 3: ...rs which are detected by the monitor Remove valve top Remove original RDSA Replace with IVM sensor RDSA Replace valve top NOTE Ferromagnetic materials such as cast iron pipe or fittings screws nails rebar or other metal items should not be placed in close proximity to the valve or monitor as these could cause incorrect operation Oct 2020 IVM6000 LPTM Quick Start Guide Page 1 a b c d IVM RDSA black...

Page 4: ...ight down over the valve In its final position the IVM6000TM must rest flush on the top of the ABS plastic valve base Line up IVM inlet over valve inlet Lower IVM down over valve IVM in final position Ensure IVM is sitting flush with the top of ABS plastic valve base Page 2 IVM6000 LPTM Quick Start Guide Oct 2020 a b c d ...

Page 5: ...00TM QUICK START STEP 3 Step 3 Supply IVM with line power and connect alarm wires to pump controller or alarm power A wiring diagram for the IVM is shown below Oct 2020 IVM6000 LPTM Quick Start Guide Page 3 ...

Page 6: ...ress the PAGE button to return to the ADMIN MENU Page 4 IVM6000 LPTM Quick Start Guide Oct 2020 PAGE Button Cycles through the various menu pages screens ALARM Button Used to clear alarms warnings and to test the alarm contacts at any time UP DOWN Buttons Used to navigate through Pages ADMIN MENU VERSION CLEAR TIME DATE POWER MENU BASIC SETTINGS ADVANCED SETTINGS TEMP SETTINGS OK button used to en...

Page 7: ...ribution for all outlets Ideally an equal amount of time is spent on each outlet The error control allows an adjustment of when an error should be signalled In the above example a 4 outlet valve should spend 25 of the time on each outlet so the 10 allowable deviation means that the value for each outlet must fall between 15 and 35 Anything outside of this range results in a percent deviation excee...

Page 8: ...ides interpretation and trouble shooting suggestions Table 2 See Appendix out lines the number of times an event has to occur to trigger an alarm for the different sensitivity settings 4 Model The current valve model and configuration In the above example a 6606 is selected which is a 6 outlet valve with 6 active outlets A 6403 is a 4 outlet valve with 3 active outlets etc Ensure this setting refl...

Page 9: ...ump controller or alarm panel by pressing the alarm button on the keypad The IVM alarm relay is by default normally open It closes when there is an alarm condition CONGRATULATIONS Your IVM6000 LP is set up and ready to give you peace of mind Oct 2020 IVM6000 LPTM Quick Start Guide Page 7 ALARM Button Used to clear alarms warnings and to test the alarm at any time Main page showing valve status and...

Page 10: ...This page intentionally left blank Page 8 IVM6000 LPTM Quick Start Guide Oct 2020 ...

Page 11: ...APPENDIX Oct 2020 IVM6000 LPTM Quick Start Guide Page 9 ...

Page 12: ...eans that there is an alarm condition and the alarm relay output has been activated See Table 1 IVM6000 Alarm Status Reference Table for a list of the various alarms warnings and events 3 Current outlet status Shows a graphical representation of the valve and activity The center circle represents the inlet while each numbered circle represents an outlet A filled dark circle represents activity whi...

Page 13: ...ing correct operation If the system and valve are functioning properly the inlet count should be close to the sum of the outlet counts Some variation will occur due to the time for the flow to reach the valve and cause the RDSA to seat Inlet time should also be very similar to the time logged by the pump dosing the valve eg Compare to the elapsed time meter ETM data for the pump Also note the IVM ...

Page 14: ...e first occurrence 2c Current date The current date 2d Current time The current time 3a Event type and code Indicates the event type Warning Info or Error Alarm and the event code For a complete list of event codes refer to Table 1 in the Appendix of this guide 3b Event description Description of the event In this example the outlet was on for less than the minimum required on time Page 12 IVM6000...

Page 15: ...occurred consecutively In this example there have been 31 consecutive instances where either outlet 2 has been off too early Note that if a different error or warning event occurs a new entry is made and a new count is started Oct 2020 IVM6000 LPTM Quick Start Guide Page 13 Keypad functions UP DOWN Cycle through stored events PAGE Go to the next screen 4 Outlets 5 Number of occurrences ...

Page 16: ...n 1c Duration The length of time that the outlet was active 2 Previous activity The second most recent active outlet 2a Time The date and time that the outlet was active 2b Activity Which outlet was active 2c Duration The length of time that the outlet was active Page 14 IVM6000 LPTM Quick Start Guide Oct 2020 Keypad functions PAGE Go to next screen 1 Most recent activity 2 Previous activity 1a Ti...

Page 17: ...me temperature conditions which may have a negative impact on the operation of the valve or sewage treatment system performance The minimum and maximum temperature values which will register a warning or trigger an alarm may be set in the ADMIN MENU TEMP SETTINGS sub menu MIN and MAX values will be reset if the IVM is cleared The IVM will take approximately one minute to display correct MIN and MA...

Page 18: ...e period counts can be used as a resettable counter similar to a trip meter in a car Note The TOTAL counts will never reset similar to an odometer in a car 3 Time Date Allows you to set the current time and date Note The time is set using 24 hour clock format Daylight savings time is not supported Page 16 IVM6000 LPTM Quick Start Guide Oct 2020 ADMIN MENU VERSION CLEAR TIME DATE POWER MENU BASIC S...

Page 19: ...seat minimum outlet on time maximum outlet on time The alarm relay configuration can also be changed from normally open N O to normally closed N C 7 Temp Settings This will bring you to a new screen that will allow you to set minimum and maximum temperature values for temperature warnings and alarms Oct 2020 IVM6000 LPTM Quick Start Guide Page 17 ADMIN MENU VERSION CLEAR TIME DATE POWER MENU BASIC...

Page 20: ...he unit completely off Nothing is monitored or logged The unit can be shut down by pressing the UP button while in this sub menu This may be useful to avoid logging false errors during sewage system start up or maintainance To wake the unit from shut down hold the OK button until the LCD turns on approximately 5 seconds Page 18 IVM6000 LPTM Quick Start Guide Oct 2020 Keypad functions UP Shutdown t...

Page 21: ...y mode and turn on the LCD if there is any activity on the valve This can be useful when at site watching for valve activity NOTE Wake mode will turn itself off after 30 minutes of use 3 Backlight Choose from OFF MED ON This sets the LCD display backlight brightness The backlight illuminates the screen for easier viewing 4 Save Save the current configuration after making changes Select SAVE then O...

Page 22: ...trols or persistent high level in pump tank Could also be caused by debris inside the valve preventing the RDSA from returning to its up position when the flow stops May not be a problem The minimum dose time pre set was not met indicates potential short cycling of the pump Ensure sensor enabled RDSA is installed and IVM is installed all the way down over valve Could also be caused by inadequate f...

Page 23: ...1 6 EVENT_INLET_NO_OUTLET 0 0 1 7 EVENT_OUT_OF_ORDER 254 8 1 8 EVENT_PCT_DEVIATION 1 1 1 9 EVENT_RESET 0 0 1 10 ETC INTERNAL USE 11 EVENT_OUTLET_STUCK 254 16 1 12 EVENT_VOLTAGE_LOW 1 1 1 13 EVENT_VOLTAGE_OK 0 0 1 14 EVENT_INAPPROPRIATE_OUTLET 1 1 1 15 ETC INTERNAL USE 16 EVENT_RTC_BATTERY_LOW 1 1 1 17 EVENT_RTC_OSCF 1 1 1 18 EVENT_CNT_CLEAR 0 0 1 19 EVENT_THERMO_WARN 254 16 1 20 EVENT_THERMO_ALARM...

Page 24: ......

Page 25: ...USIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS IMPLIED OR STATUTORY INCLUDING ANY LIABILITY ARISING UNDER ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE STATUTORY OR OTHERWISE THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS WHICH MAY VARY IN DIFFERENT JURISDICTIONS IN NO EVENT SHALL DYNAMIC MONITORS OR ENGINEERING TECHNOLOGIES CANADA LTD BE LIABLE FOR ANY INCIDENTAL S...

Page 26: ...unctions The distributing valve Intelligent Valve MonitorTM combination offers superior reliability and control system simplicity compared to using solenoid or motor actuated valves for zoning effluent distribution systems It is also much less costly than using larger pumps or many additional pumps which increases control panel complexity The monitors provide peace of mind that the valves are dist...

Page 27: ...Patent Pending Dynamic Monitors is a developer of innovative electronic monitoring devices for the environmental sector and is not affiliated with K Rain Corporation of West Palm Beach FL Toll free 1 888 747 7645 Direct 1 902 628 1705 IVM DynamicMonitors com Product Specifications Valve Cam Model All 6000 series 2 3 4 5 or 6 outlets Line power Any from 6V 30V AC or DC Use standard 24V AC 40VA tran...