Page 3
3002xTJ32 MANUAL - FORM 3002TJ-003
MODEL 3002xTJ32
ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
02/07
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
Repeat process for second
armature mounting bracket.
ATTACH THE ARMATURE TO THE ARMATURE MOUNTING BRACKET
ASSEMBLE THE ARMATURE MOUNTING BRACKET
Locate the two armature mounting bracket
assembly screws and lock washers from
the hardware kit and assemble the bracket
as shown.
Firmly tighten the mounting screws with a
5/32” hex wrench. They may be loosened
later for adjustment, as necessary.
Attach the Armature Housing to the top Armature Mounting Bracket using four (4) 8-32x3/8” Armature Housing
Screws.
Attach the armature to the armature mounting bracket as shown for LH door (Use alternate holes for RH door).
Firmly tighten the Armature Mounting Screw using a 3/16” hex wrench.
Failure to properly secure the armature to the bracket could result in serious injury or possible security
breach.
UPPER ARMATURE
BRACKET
LOWER ARMATURE BRACKET
LOCK WASHER
BRACKET ASSEMBLY SCREW
ARMATURE
SPACER
FLAT
STEEL WASHER
ARMATURE
MOUNTING
SCREW
ARMATURE MOUNTING BRACKET
ARMATURE HOUSING
ARMATURE
ARMATURE HOUSING SCREW
Repeat process for second armature mounting bracket.