background image

Congratulations!

 With buying a DYNACORD CL-SERIES power amplifier you have chosen an appli-

ance that employs most advanced technology.

CL-Series power amps combine outstanding audio performance, highest reliability and operational 

safety. 

The audio performance of CL power amps are simply extraordinary. Optimised power supply units em-

ploying low-leakage toroidal transformers and the consistent use of Class-H technology provide exten-

sive headroom far above the stated nominal output. At the same time this contributes to a reduction in 

weight and power dissipation.

The  CL1200/1600/2000  is  designed  in  Class-H  technology,  i.e.  the  power  amp  provides  extremely 

fast, signal-dependent operating voltage switching, which results in doubling the regular supply voltage 

when needed. Compared to Class-AB power amps, Class-H power amps generate by far less power 

dissipation at identical output. Consequently, reduced leakage power or dissipation is synonymous to 

less waste heat – energy is used more efficiently. As a result, installing Class-H power amps within rack 

shelf systems is possible with less space between appliances. In addition to that and despite offering 

identical output, power consumption is a lot less than in Class-AB operation.

DYNACORD  CL-SERIES  power  amps  have  been  designed  to  fulfil  even  the  most  demanding 

requirements  of  touring  applications.  CL-Series  amps  are  protected  against  thermal  and  electrical 

overload, short circuit and the occurrence of HF/DC at the outputs. Back-EMF-Protection eliminates 

the risk of the output transistors being damaged by electrical energy back-feed. The power outputs are 

switched via relay with a time delay during soft-start. An inrush current limiter prevents mains fuses from 

blowing.

Mechanical  construction  and  workmanship  also  comply  with  the  highest  precision  manufacturing 

standards. The rigid sheet steel chassis even resists the most wearing tour operation. Two three-speed 

high performance fans (off/slow/fast) guarantee outstanding thermal stability at absolute low running 

noise. The ventilation is directed front-to-rear allowing trouble-free operation even in smaller amp-racks. 

The  electronically  balanced  inputs  are  carried  out  via  XLR-type  connectors.  Direct-Outs  for  through 

connecting the audio signal are also provided via XLRM-type connectors. Input Routing allows selecting 

DUAL (stereo) or PARALLEL (monaural) operation mode. By means of the separate BRIDGED OUT-

connector and a Bridged Mode-switch, switching to „Mono Bridged“ operation is truly uncomplicated 

as well. The recessed mounted dB-scaled level controls ensure reliable protection against mechanical 

damage.  These  particularly  precise,  secure  to  operate  detent-potentiometers  are  located  on  the 

front panel. CL-Series power amps provide the opportunity for retrofitting an internal analogue signal 

processor board with x-over and filter functions.

The  easily  readable  LED  display  provides  a  quick  overview  of  the  power  amp’s  current  operational 

status. The power outputs CHANNEL A, CHANNEL B and BRIDGED OUT are carried out as extremely 

durable SPEAKON-type connectors. Also located on the rear panel is a Ground-lift switch, which helps 

eliminating  ground-noise  loops  by  separating  the  power  amp’s  enclosure  from  the  circuit  ground.  In 

normal operation, all CL-Series power amps are capable of driving loads as low as 2ohms. In Mono-

Bridged mode the allowable minimum load is 4ohms.

This owner’s manual outlines and explains several other features of your CL-Series power amplifier. 
Please, make sure to carefully read all of it and mind the instructions.

DESCRIPTION

4

Summary of Contents for CL 1200

Page 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI LINEAR PRECISION POWER AMP...

Page 2: ...LLAGE ET GARANTIE 25 REMARQUES SUR L INSTALLATION 25 FACE AVANT 26 PANNEAU ARRI RE 27 INPUT A INPUT B 27 PARALLEL 27 SORTIE DE AMPLI DE PUISSANCE 28 GROUND LIFT 28 ENTR E SECTEUR 28 SECTEUR ET TEMP RA...

Page 3: ...filled with liquids such as vases are placed on the equipment 16 To completely disconnect this equipment from the AC Mains disconnect the power plug from the AC receptacle 17 The mains plug of the pow...

Page 4: ...limiter prevents mains fuses from blowing Mechanical construction and workmanship also comply with the highest precision manufacturing standards The rigid sheet steel chassis even resists the most wea...

Page 5: ...easily rise up to 40 C during operation bearing in mind the maximally allowable environmental temperature during operation for all other appliances installed in the same rack shelf system is mandatory...

Page 6: ...ters This indicator lights as soon as the integrated dynamic audio signal limiter is activated and the power amplifier is driven at the clipping limit or generally at its maximum capacity Short term b...

Page 7: ...of the cable s plugs unconnected is necessary Otherwise when feeding in unbalanced audio signals via PIN3 b cold and PIN2 a hot strange humming and RF interference may occur which very likely will dam...

Page 8: ...aker systems match the specifications of the power amplifier GROUND LIFT SWITCH The ground lift switch allows eliminating noise loops If the power amplifier is operated together with other equipment i...

Page 9: ...2 8 440 2 x 40 360 1230 Rated Output Power 0dB 4 1 230V 6 4 1130 2 x 300 530 1810 Alert Alarm Mode 3dB 4 1 230V 4 9 820 2 x150 520 1775 Max Output Power 2 1 230V 11 2 2150 2 x 600 950 3240 1 8 Max Out...

Page 10: ...W Pout W Pd 6 W BTU hr 4 idle 230V 0 6 72 72 246 Max Output Power 8 1 230V 10 0 1712 2 x 600 512 1747 Max Output Power 4 1 230V 16 3 2991 2 x 1000 991 3381 1 3 Max Output Power 4 1 230V 9 7 1646 2 x 3...

Page 11: ...BEDIENUNGSANLEITUNG LINEAR PRECISION POWER AMP...

Page 12: ...CKEN GARANTIE 15 INSTALLATIONSHINWEISE 15 FRONTSEITE 16 R CKSEITE 17 INPUT A INPUT B 17 PARALLEL 17 ENDSTUFENAUSG NGE 18 BRIDGED MODE 18 GROUND LIFT SCHALTER 18 NETZEINGANG 18 NETZBETRIEB W RMEENTWICK...

Page 13: ...und Weise besch digt beispielsweise das Netzkabel oder der Netzstecker wurden besch digt Fl ssigkeit oder ein Fremdk rper ist in das Ger teinnere eingedrungen das Ger t wurde Regen oder hoher Luftfeu...

Page 14: ...tet Zus tzlich verhindert eine Einschaltstrombegrenzung das Ansprechen von Netzsicherungen H chste Pr zision ist auch in der mechanischen Konstruktion und Verarbeitung gew hrleistet Das robuste Stahlb...

Page 15: ...chrank bis zu 40 C ansteigen kann muss die maximal zul ssige Umgebungstemperatur der brigen im Gestellschrank befindlichen Ger te beachtet werden siehe auch Kapitel NETZBETRIEB UND W RMEENTWICKLUNG Ac...

Page 16: ...sobald einer der eingebauten dynamische Audio Limiter anspricht und die Endstufe ber der Aussteuerungsgrenze oder generell im Grenz bereich betrieben wird Kurzzeitiges Aufleuchten ist dabei unproblem...

Page 17: ...en Sie am besten symmetrisch ausgelegte Kabel 2 Signaladern Schirm geflecht mit XLR Stecker Obwohl alle Endstufeneing nge auch unsymmetrisch beleget werden k nnen stellt ein symmetrisch ausgef hrtes N...

Page 18: ...eiligen Lautsprechers und vergleichen Sie diese mit der entsprechenden Ausgangsleistung der Endstufe GROUND LIFT SCHALTER Mit dem Groundlift Schalter k nnen Sie Brummschleifen verhindern Wenn die Ends...

Page 19: ...0 360 1230 Rated Output Power 0dB 4 1 230V 6 4 1130 2 x 300 530 1810 Alert Alarm Mode 3dB 4 1 230V 4 9 820 2 x150 520 1775 Max Output Power 2 1 230V 11 2 2150 2 x 600 950 3240 1 8 Max Output Power 2 1...

Page 20: ...hen 3 Rosa Rauschen gem EN60065 7 Edition 4 1BTU 1055 06J 1055 06Ws 5 10 Netz berspannung 6 Pd Verlustleistung Die Stromaufnahme f r andere Netze k nnen mit folgenden Faktoren direkt proportional umge...

Page 21: ...MODE D EMPLOI LINEAR PRECISION POWER AMP...

Page 22: ...DESCRIPTION 24 D BALLAGE ET GARANTIE 25 REMARQUES SUR L INSTALLATION 25 FACE AVANT 26 PANNEAU ARRI RE 27 INPUT A INPUT B 27 PARALLEL 27 SORTIE DE AMPLI DE PUISSANCE 28 GROUND LIFT 28 ENTR E SECTEUR 28...

Page 23: ...ionne pas normalement ou s il est tomb 15 N exposez pas cet quipement aux claboussures et veillez ce qu aucun r cipient rempli de liquide verre ou vase ne soit pos dessus 16 Pour d connecter compl tem...

Page 24: ...d appel de courant vite que les fusibles secteur ne sautent Leur construction m canique et quasiment artisanale ach ve de parfaire une fabrication de haute pr cision Le ch ssis en acier est con u pour...

Page 25: ...rieur du meuble ou du rack peut monter facilement 40 C pendant le fonctionnement v rifiez que la temp rature ambiante maximale autoris e en fonctionnement pour tous les autres appareils pr sents dans...

Page 26: ...ge de limiteurs externes Ce t moin s allume d s que le limiteur de signal audio dynamique int gr entre en action et que l amplificateur de puissance arrive la limite de l cr tage ou plus g n ralement...

Page 27: ...une tresse de masse munis de prises de type XLR Bien que le branchement de c bles non sym tris s l amplificateur de puissance soit possible il est toujours pr f rable d utiliser des c bles sym tris s...

Page 28: ...tensions Veuillez v rifier que les caract ristiques de puissance mentionn es dans la documentation fournie avec vos haut parleurs correspondent celles de l amplificateur de puissance COMMUTATEUR DE MA...

Page 29: ...dB 4 1 230V 2 8 440 2 x 40 360 1230 Rated Output Power 0dB 4 1 230V 6 4 1130 2 x 300 530 1810 Alert Alarm Mode 3dB 4 1 230V 4 9 820 2 x150 520 1775 Max Output Power 2 1 230V 11 2 2150 2 x 600 950 3240...

Page 30: ...55 06 W s 5 10 au dessus de la tension secteur 6 Pd Puissance dissip e Les facteurs suivants permettent un calcul proportionnel direct du courant secteur Imain pour diff rentes alimentations secteur 1...

Page 31: ...z 7kHz 0 02 DIM 30 3 15kHz 15kHz 0 01 Maximum Input Level 22 dBu 9 76 V rms Crosstalk ref 1kHz at rated output power 80 dB Frequency Response ref 1kHz 1dB 15Hz 40kHz Input Impedance active balanced 20...

Page 32: ...BLOCK DIAGRAM 32...

Page 33: ...ABMESSUNGEN DIMENSIONS ABMESSUNGEN DIMENSIONS in mm 33...

Page 34: ...NOTES 34...

Page 35: ...NOTES 35...

Page 36: ...2 884 0043 Germany EVI AUDIO GmbH Hirschberger Ring 45 D 94315 Straubing Germany Phone 49 9421 706 0 FAX 49 9421 706 265 France EVI AUDIO France Parc de Courcerin All e Lech Walesa 77185 Lognes France...

Reviews: