33. Check the filter for tears or small holes. If none are 

found, reinstall the filter. To prevent damage to your 

vacuum, do not use a filter with a hole or a tear.

34. Use the disposable filter bag in conjunction with the 

cartridge filter for easy disposal of the debris. The bag 

is not required for normal dry pick up. When picking up 

fine dust or powders a high efficiency filter bag must 

be used. 

NOTE:

 

Use for dry pick up only.

35. With cord disconnected from the receptacle, pull 

latches in an outward motion and remove the tank 

cover.

39. Slide the inlet deflector with the 

filter bag attached into the deflector 

guide. 

FIGURE 33

.

36. Unscrew hose locking-nut and 

remove hose from inlet. 

FIGURE 30

.

37. Remove the inlet deflector from 

the deflector guide. 

NOTE:

 Hose 

must be removed before the inlet 

deflector can be taken out. 

FIGURE 31

38. Position the inlet deflector with 

the opening facing the left or the 

right side of the filter bag. Slide the 

filter bag collar over the inlet deflec-

tor, matching the notches of the bag 

collar to the tabs on the inlet 

deflector. Bag will only fit properly  

one way. 

FIGURE 32

.

40. Reinsert hose into inlet and 

tighten the locking-nut. 

FIGURE 34

.

KEEP FILTERS CLEAN. EFFICIENCY OF THE VACUUM 

IS LARGELY DEPENDENT ON THE FILTER. A CLOGGED 

FILTER CAN CAUSE OVERHEATING AND POSSIBLY 

DAMAGE THE CLEANER. CHECK THE FILTER 

PERIODICALLY AND REPLACE AS REQUIRED.

INSTALLING THE DISPOSABLE FILTER BAG:

ALWAYS DISCONNECT THE 

PLUG FROM THE WALL 

OUTLET BEFORE REMOVING 

THE TANK COVER.

41. When secured in place, expand the filter bag and 

position around the inside of the tank. Replace tank 

cover.

NOTE:

 When removing filter bag from tank, remove the 

inlet deflector from the filter bag collar. Reinstall inlet 

deflector into deflector guide. Inlet deflector must be in 

place for any type of cleaning.

FOR FINE DUST POWDERS

When vacuuming fine dust, or powders of 

any kind (plaster, drywall dust, cold ashes, 

concrete dust, etc.) a high efficiency 

drywall filter bag must be used. When vacuuming

normal household dust and debris, standard household

disposable filter bags may be used. 

PAGE 9

by rinsing outside surface of filter with running water. 

Avoid dampening inside of filter. Completely air dry filter 

after washing. 

FIGURE 25.

   

32. Important: DO NOT BRUSH. DO NOT clean filter 

media with abrasive materials. DO NOT scrub to clean 

between pleats. This will permanently damage the 

filter’s ability to stop dust and will void warranty.

WET PICK UP 

OPERATION

42. Your vacuum can be used for wet pick up. Remove 

ALL dirt and debris found in the tank. Remove all 

dry use only filters, including the filter bag, from the 

vacuum.  

43. A clean cartridge filter may be used to pick up small 

quantities of liquid. To use the cartridge filter; follow the 

cleaning and installation instructions under dry pick up. 

Summary of Contents for Mini-Raptor Vac 61100

Page 1: ...031 dynabrade com USER MANUAL Mini Raptor Vac WET DRY VAC COMMERCIAL USE 87557 34 Tank capacity refers to actual tank volume and does not reflect capacity available during operation 16 60 5 FOR YOUR SAFETY READ ALL INSTRUCTIONS CAREFULLY BEFORE USE SAVE THIS MANUAL FOR FUTURE REFERENCE LITER U S GALLON Model 61100 ...

Page 2: ...Filter Installation and Cleaning Dry Pick Up Operation Wet Pick Up Operation Blower Feature Emptying Liquid Waste Automatic Suction Shut Off Lubrication Storage Troubleshooting Warranty Information Filter Replacement Contact Us CATALOG MODEL NUMBERS Catalog No 9751601 Model No 61100 Date of Purchase For your records please record your Date of Purchase and store this owner s manual in a safe locati...

Page 3: ...New York 14031 dynabrade com CARTON CONTENTS WARNING REVIEW IMPORTANT SAFETY INSTRUCTIONS BEFORE USE TOOLS REQUIRED Vacuum Cartridge filter Filter Retainer HE filter bag Screws 4 Handles 2 Handle supports 4 Hose end 1 1 Safety Glasses Flathead Screwdriver Check to make sure you have the following PAGE 3 ...

Page 4: ... or appliance with wet hands 9 Do not put any object into openings Do not use with any openings blocked keep free of dust lint hair and anything that may reduce air flow 10 Keep hair loose clothing fingers and all parts of body away from openings and moving parts 11 Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes 12 Do not use without dust bag and or filt...

Page 5: ...not available The temporary adapter should be used only until a properly grounded outlet SKETCH A can be installed by a qualified electrician The green colored rigid ear lug or the like extending from the adapter WARNING WARNING GROUNDING INSTRUCTIONS must be connected to a permanent ground such as a properly grounded outlet box cover Whenever the adapter is used it must be held in place by a meta...

Page 6: ...More Than Not More Than TABLE A PAGE 6 a b c d e 3 Place one hair pin in one end of the axle FIGURE 2 4 Slide on one washer FIGURE 3 5 Slide wheel onto axle next to washer FIGURE 4 Be sure flat side of wheel hub is facing outward 6 Slide on one washer FIGURE 5 7 Slide axle through holes provided in tool rack FIGURE 6 8 Slide on one washer Slide remaining wheel then washer onto axle end FIGURE 7 1 ...

Page 7: ...f the tank FIGURE 17 13 Remove any webbing that attaches the tank handles to each other Take the side tank handle with the letter L and position it on the outside of the tank where the support assemblies are installed The U shaped cutout on the bottom end of the handle must face the rear of the tank Secure the handle to the tank with the screws in the support assemblies FIGURE 18 15 Position metal...

Page 8: ...ver the lid cage pushing until the filter seals against the cover FIGURE 24 27 Place filter retainer into the top of the cartridge filter FIGURE 25 25 The cartridge filter can be used for dry pick up and small quantities of wet pick up Installation is the same FIGURE 23 23 Attach one of the cleaning accessories depending on your cleaning requirements on the extension wands Twist slightly to tighte...

Page 9: ...LEAN EFFICIENCY OF THE VACUUM IS LARGELY DEPENDENT ON THE FILTER A CLOGGED FILTER CAN CAUSE OVERHEATING AND POSSIBLY DAMAGE THE CLEANER CHECK THE FILTER PERIODICALLY AND REPLACE AS REQUIRED INSTALLING THE DISPOSABLE FILTER BAG ALWAYS DISCONNECT THE PLUG FROM THE WALL OUTLET BEFORE REMOVING THE TANK COVER 41 When secured in place expand the filter bag and position around the inside of the tank Repl...

Page 10: ...ver Clean and allow the filters to dry completely NOTE WET PICK UP ACCESSORIES SHOULD BE WASHED PERIODICALLY ESPECIALLY AFTER PICKING UP WET STICKY KITCHEN ACCIDENTS THIS CAN BE ACCOMPLISHED WITH A WARM SOLUTION OF SOAP AND WATER AUTOMATIC SUCTION SHUT OFF 54 The vacuum is equipped with an automatic suction shut off that operates when picking up liquids As the level of the liquid rises in the tank...

Page 11: ...f unit FIGURE 37 TROUBLESHOOTING PROBLEM CAUSE SOLUTION Loss of suction wet pick up Loss of suction dry pick up Loss of suction or misting during wet pick up Clogged filter Clogged filter Full tank Full tank Saturated filter Clean filter see steps 29 33 on page 7 and steps 49 52 on page 9 Clean filter see steps 29 33 on page 7 Drain and clean tank see step 54 on page 9 Clean filter see steps 45 on...

Page 12: ...PROUDLY DESIGNED ENGINEERED AND BUILT IN AMERICA SINCE 1969 Dynabrade Inc 8989 Sheridan Drive Clarence New York 14031 dynabrade com PROUDLY PAGE 12 ...

Page 13: ...5 Screw 10 x Trilobe Twin Lead Blower Port Cap Includes 9 Foam Diffuser Hose Holder Power Unit Assembly Ball Float Lid Latch Lid Cage Latch Assembly Disposable Filter Bag Cartridge Filter Filter Retainer Tank Assembly Carriage Handle Handle and Hardware PKG Includes 21 25 Side Tank Handle Right Side Tank Handle Left Screw x 1 Hex Head Handle Support Screw 10 x 1 Hex Head Accessory Basket 2 Inlet D...

Page 14: ......

Reviews: