      disperse fine lead particles into the air.  This 

      vacuum cleaner is not intended for use under EPA

      Regulation 40 CFR Part 745 for lead paint material 

      cleanup.

DO NOT LEAVE VACUUM 

UNATTENDED WHEN IT 

IS PLUGGED IN AND/OR 

OPERATING. UNPLUG UNIT 

WHEN NOT IN USE.

This appliance must be grounded. If it should 

malfunction or breakdown, grounding provides a path 

of least resistance for electric current to reduce the 

risk of electric shock. This appliance is equipped with 

a cord having an equipment-grounding conductor 

and grounding plug. The plug must be inserted into 

an appropriate outlet that is properly installed and 

grounded in accordance with all local codes and 

ordinances.

IMPROPER CONNECTION OF THE EQUIPMENT-

GROUNDING CONDUCTOR CAN RESULT IN A 

RISK OF ELECTRIC SHOCK. CHECK WITH A 

QUALIFIED ELECTRICIAN OR SERVICE PERSON 

IF YOU ARE IN DOUBT AS TO WHETHER THE 

OUTLET IS PROPERLY GROUNDED. DO NOT 

MODIFY THE PLUG PROVIDED WITH THE 

APPLIANCE – IF IT WILL NOT FIT THE OUTLET, 

HAVE A PROPER OUTLET INSTALLED BY A 

QUALIFIED ELECTRICIAN. 

This appliance is for use on a nominal 120-volt circuit, 

and has a grounded plug that looks like the plug 

illustrated in 

SKETCH A

. A temporary adapter that looks 

like the adapter illustrated in 

SKETCHES B and C

 may 

be used to connect this plug to a 2-pole receptacle as 

shown in 

SKETCH B

 if a properly grounded outlet is not 

available. The temporary adapter should be used only 

until a properly grounded outlet 

(SKETCH A)

 can be 

installed by a qualified electrician. The green colored 

rigid ear, lug or the like extending from the adapter 

    

WARNING!

    

WARNING!

GROUNDING 

INSTRUCTIONS

must be connected to a permanent ground such as 

a properly grounded outlet box cover. Whenever the 

adapter is used, it must be held in place by a metal 

screw.

IN CANADA, THE USE OF A TEMPORARY ADAPTOR 

IS NOT PERMITTED BY THE CANADIAN ELECTRICAL 

CODE. Make sure that the appliance is connected to 

an outlet having the same configuration as the plug. No 

adapter should be used with this appliance.

When using the appliance at a distance where an 

extension cord becomes necessary, a 3-conductor 

grounding cord of adequate size must be used for 

safety, and to prevent loss of power and overheating. 

Use 

TABLE A

 to determine A.W.G. wire size required. 

To determine ampere rating of your vacuum, refer to 

nameplate located on motor housing.

Before using appliance, inspect power cord for loose 

or exposed wires and damaged insulation. Make any 

needed repairs or replacements before using your 

appliance. Use only three-wire outdoor extension cords, 

which have three-prong grounding-type plugs and three-

pole receptacles which accept the extension cord’s plug. 

When vacuuming liquids, be sure the extension cord 

connection does not come in contact with the liquid.

NOTE:

  STATIC SHOCKS ARE COMMON IN DRY AREAS 

OR WHEN THE RELATIVE HUMIDITY OF THE AIR IS 

LOW. THIS IS ONLY TEMPORARY AND DOES NOT 

AFFECT THE USE OF THE APPLIANCE. TO REDUCE 

THE FREQUENCY OF STATIC SHOCKS IN YOUR HOME, 

SKETCH A

SKETCH B

SKETCH C

EXTENSION

CORDS

SAVE THESE

INSTRUCTIONS

PAGE 5

Summary of Contents for Mini-Raptor Vac 61100

Page 1: ...031 dynabrade com USER MANUAL Mini Raptor Vac WET DRY VAC COMMERCIAL USE 87557 34 Tank capacity refers to actual tank volume and does not reflect capacity available during operation 16 60 5 FOR YOUR SAFETY READ ALL INSTRUCTIONS CAREFULLY BEFORE USE SAVE THIS MANUAL FOR FUTURE REFERENCE LITER U S GALLON Model 61100 ...

Page 2: ...Filter Installation and Cleaning Dry Pick Up Operation Wet Pick Up Operation Blower Feature Emptying Liquid Waste Automatic Suction Shut Off Lubrication Storage Troubleshooting Warranty Information Filter Replacement Contact Us CATALOG MODEL NUMBERS Catalog No 9751601 Model No 61100 Date of Purchase For your records please record your Date of Purchase and store this owner s manual in a safe locati...

Page 3: ...New York 14031 dynabrade com CARTON CONTENTS WARNING REVIEW IMPORTANT SAFETY INSTRUCTIONS BEFORE USE TOOLS REQUIRED Vacuum Cartridge filter Filter Retainer HE filter bag Screws 4 Handles 2 Handle supports 4 Hose end 1 1 Safety Glasses Flathead Screwdriver Check to make sure you have the following PAGE 3 ...

Page 4: ... or appliance with wet hands 9 Do not put any object into openings Do not use with any openings blocked keep free of dust lint hair and anything that may reduce air flow 10 Keep hair loose clothing fingers and all parts of body away from openings and moving parts 11 Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes 12 Do not use without dust bag and or filt...

Page 5: ...not available The temporary adapter should be used only until a properly grounded outlet SKETCH A can be installed by a qualified electrician The green colored rigid ear lug or the like extending from the adapter WARNING WARNING GROUNDING INSTRUCTIONS must be connected to a permanent ground such as a properly grounded outlet box cover Whenever the adapter is used it must be held in place by a meta...

Page 6: ...More Than Not More Than TABLE A PAGE 6 a b c d e 3 Place one hair pin in one end of the axle FIGURE 2 4 Slide on one washer FIGURE 3 5 Slide wheel onto axle next to washer FIGURE 4 Be sure flat side of wheel hub is facing outward 6 Slide on one washer FIGURE 5 7 Slide axle through holes provided in tool rack FIGURE 6 8 Slide on one washer Slide remaining wheel then washer onto axle end FIGURE 7 1 ...

Page 7: ...f the tank FIGURE 17 13 Remove any webbing that attaches the tank handles to each other Take the side tank handle with the letter L and position it on the outside of the tank where the support assemblies are installed The U shaped cutout on the bottom end of the handle must face the rear of the tank Secure the handle to the tank with the screws in the support assemblies FIGURE 18 15 Position metal...

Page 8: ...ver the lid cage pushing until the filter seals against the cover FIGURE 24 27 Place filter retainer into the top of the cartridge filter FIGURE 25 25 The cartridge filter can be used for dry pick up and small quantities of wet pick up Installation is the same FIGURE 23 23 Attach one of the cleaning accessories depending on your cleaning requirements on the extension wands Twist slightly to tighte...

Page 9: ...LEAN EFFICIENCY OF THE VACUUM IS LARGELY DEPENDENT ON THE FILTER A CLOGGED FILTER CAN CAUSE OVERHEATING AND POSSIBLY DAMAGE THE CLEANER CHECK THE FILTER PERIODICALLY AND REPLACE AS REQUIRED INSTALLING THE DISPOSABLE FILTER BAG ALWAYS DISCONNECT THE PLUG FROM THE WALL OUTLET BEFORE REMOVING THE TANK COVER 41 When secured in place expand the filter bag and position around the inside of the tank Repl...

Page 10: ...ver Clean and allow the filters to dry completely NOTE WET PICK UP ACCESSORIES SHOULD BE WASHED PERIODICALLY ESPECIALLY AFTER PICKING UP WET STICKY KITCHEN ACCIDENTS THIS CAN BE ACCOMPLISHED WITH A WARM SOLUTION OF SOAP AND WATER AUTOMATIC SUCTION SHUT OFF 54 The vacuum is equipped with an automatic suction shut off that operates when picking up liquids As the level of the liquid rises in the tank...

Page 11: ...f unit FIGURE 37 TROUBLESHOOTING PROBLEM CAUSE SOLUTION Loss of suction wet pick up Loss of suction dry pick up Loss of suction or misting during wet pick up Clogged filter Clogged filter Full tank Full tank Saturated filter Clean filter see steps 29 33 on page 7 and steps 49 52 on page 9 Clean filter see steps 29 33 on page 7 Drain and clean tank see step 54 on page 9 Clean filter see steps 45 on...

Page 12: ...PROUDLY DESIGNED ENGINEERED AND BUILT IN AMERICA SINCE 1969 Dynabrade Inc 8989 Sheridan Drive Clarence New York 14031 dynabrade com PROUDLY PAGE 12 ...

Page 13: ...5 Screw 10 x Trilobe Twin Lead Blower Port Cap Includes 9 Foam Diffuser Hose Holder Power Unit Assembly Ball Float Lid Latch Lid Cage Latch Assembly Disposable Filter Bag Cartridge Filter Filter Retainer Tank Assembly Carriage Handle Handle and Hardware PKG Includes 21 25 Side Tank Handle Right Side Tank Handle Left Screw x 1 Hex Head Handle Support Screw 10 x 1 Hex Head Accessory Basket 2 Inlet D...

Page 14: ......