Page
2
of
28
ROUTINE MAINTENANCE FOR MODELS CD/SS
-IT
•
This unit must be filled at all times with either mineral oil, water or any other neutralizing liquid
required for the product being recovered.
•
This unit must be filled up to the liquid level indicator l
ine shown on the recovery drum.
•
Do not exceed the recommended maximum dust recovery capacity.
Model
Max.
dust
recover
y
capacit
y
Neutralizin
g
liquid
required
SS-IT
EX
TC
15
lbs
/
7
k
g
5.3
g
allons
/
20
liters
CD/SS-IT
(
85L
)
22
lbs
/
10
k
g
7.9
g
allons
/
30
liters
CD/SS-IT
(
114L
)
33
lbs
/
15
k
g
11.9
g
allons
/
45
liters
CD/SS-IT
(
160L
)
44
lbs
/
20
k
g
15.8
g
allons
/
60
liters
•
When maximum capacity is reached the first step is to drain the neutralizing liquid by opening up the
manifold drain valve.
•
Once drained the unit must be disconnected from its power source – either from the electrical outlet or
from the air compressor.
•
Disconnect the power head (if applicable) and all hoses from the top lid.
•
Open all latches.
•
Remove all parts off of the recovery drum.
•
Remove the sieve basket from inside of the recovery
drum. Discard all recovered material from inside
of the sieve basket.
•
Thoroughly clean all parts of the unit, including the sieve basket and suction hoses.
•
Once unit is clean reinstall sieve basket inside the recovery drum and fill it of clean neutralizing liquid.
COALESCING FILTER ELEMENT (CFE)
The Coalescing Filter Element (CFE) is located downstream of
the recovery drum at the air exhaust. Verify
if
the CFE needs to be drained or replaced as part of r
outine maintenance. The CFE can be
removed from the
unit and washed from the inside and then dried and reused several times.
PLEASE CONSULT THE INSTRUCTION MANUAL AT ALL TIMES