Metal Capture Station Machine Setup
3
Next you will need to provide a power
source for your machine. Refer to the parts
page, as the model number will be used for
determining the voltage rating for your
specific machine.
Warning:
DO NOT attempt to wire the machine for
any other voltage other than that stated for
your model. There are internal components
to the control box that are voltage specific
and failure to provide proper voltage can
cause damage to your machine and could
cause personal injury.
Model: 64300, NEMA L15-20 shown
Before plugging in your machine, be sure
that the lockout disconnect is in the “Off”
position.
Note:
The disconnect is used as a lockout
mechanism. For any maintenance required
inside the control box, the disconnect will
need to be in the off position to open the
access door. If the disconnect is in the on
position, the access door will remain
locked.
After plugging your machine in, proceed to
move the lockout disconnect to the “On”
position, providing power to the machine
and sensory controls. Once power has
been provided, the green pilot light will
start a flashing sequence for a 25 second
set-up stage. The auto-fill system will take
over after the set-up stage is complete and
bring the machines water level to the
correct height before allowing the operator
to turn on the machine. At the time the
green pilot light glows solid, the machine is
then ready to start.
6
5
7
64300: NEMA L15-20 250 VAC 20A
64304: NEMA L16-20 480 VAC 20A
64350: NEMA L15-20 250 VAC 20A
64354: NEMA L16-20 480 VAC 20A