USE R GUI DE
|
P OR T A -R AY
®
4 0 0 R
9
Figure 6.
Unlatching the Lamp Head
from the Storage Compartment
Figure 7.
Removing the Lamp Head from the Storage
Compartment
Figure 8.
Lamp Head on Headrest
System Operation
The PORTA-RAY 400R is designed to be an extremely user-friendly
system. This system was designed with minimum controls, making it
easy to operate.
Start Up
Open the Latches on the side of the storage compartment unit, and remove the Lamp Head from the bottom enclosure
by lifting it by the Handle (Figure 6 &
2.
Place the Lamp Head on the Headrest with the drawer closed
(Figure 8).
3.
Plug the IEC-Type Connector of the AC Power Cord into the
Power Input Receptacle in the side of the Lamp Head. Plug in
the opposite end of the Input Line Cord into a nearby single-
phase power outlet.
4.
To start the system, turn on the Power Switch (Figure 2, B) at
the side of the unit. The Lamp Head should turn on.
5.
During the warm-up period, the Lamp Power Select Switch
(Figure 2, D) on the top of the Lamp Head should be set to full
power mode. A one- to two-minute warm-up time is required
for the Lamp to reach full intensity.
WARNING!
Bluish light is projected from the unit,
becoming brighter as the unit warms up. This
ultraviolet light can be harmful to the eyes and skin. UV
protective glasses and clothing are required to prevent burns
of eyes and skin. Care should also be taken to protect other
personnel in the area from unintentional exposure to the UV
light (see the safety section for additional UV safety
information).
6.
To change to the standby power mode, switch the Lamp Power
Selector Switch (Figure 2, D) to the half power position (Rocker
Paddle pressed toward the closest Handle stem). The Lamp
Head intensity will visibly dim when the unit is in this low-power
mode.
NOTE:
The PORTA-RAY 400R system is designed for
continuous operation. It is suggested that the Lamp remain on
during work breaks. Frequent stopping and starting of the
Lamp Head will reduce Lamp Head life. In general, leave the
unit in standby power mode for periods of non-use of less than
30 minutes. The unit will require only a brief 10 second re-