Specifications
Property
Specifications
Part Numbers
39639
120 VAC, Metal Halide Bulb
39640
240 VAC Metal Halide Bulb
39697
120 VAC, Mercury Bulb
39713
240 VAC Mercury Bulb
Typical Output Intensity
400 @ UV-A* (365 nm)
Dimensions (L x W x H)
8" x 5" x 16.5" [20.3 cm x 12.7 cm x 41.9 cm]
Weight
With bottom box: 6 lbs. / With lamp head only: 3.5 lbs.
Max Chamber Part Size
(for curing in Headrest)
4.25" x 4.25" x 2" [10.8 cm x 10.8 cm x 5.1 cm]
Po
wer
S
u
ppl
y
Input Voltage
100-120 VAC + -10%
200-240 VAC + -10%
Input Current (max)
7 Amperes
3.5 Amperes
Source Input Frequency
47 Hz to 63 Hz
Lamp Power Regulation
± 1%
Protection
Inrush current limit, hot re-strike, line
voltage surge, short circuit, open circuit,
over temperature, ignition retry timeout
5 minutes
La
mp
Lamp Type
400 Watt metal halide
Quartz, ozone free
Lamp Voltage
135 ± 15V
Arc Length
32 mm
Burning Position
Horizontal
Radiation Flux
72 Watts, 315-440 nm
Warm-Up Time (min)
1-2
Cooling Time Before
Restart
5 minutes (typical)
Lamp protection prevents the restart of a
hot lamp
Lamp Peak Irradiance
500 mW/cm
2
UVA
2" from base of lamp head
Curing Area (minimum)
5" x 3" [12.7 cm x 7.62 cm]
Affected by lamp height
Lamp Life
1,000 hours typical
Affected by # of on/off cycles
En
vi
ro
n
men
ta
l
Operating Temperature
+10 °C to +40 °C (+50 °F to +104 °F)
Storage Temperature
0 °C to +60 °C (+32 °F to +140 °F)
Relative Humidity
30 to 75% operating, 10 to 100% storage, non-condensing
Cooling
Forced air
Over-Temp Shutdown
67°C (internal)
* Intensity with the beam focused and measured with an ACCU-C
AL™