U S E R G U I D E
|
B L U E W A V E
®
Q X 4
®
WARNING!
UV emitted from this product. Avoid eye and skin exposure to
unshielded products.
WARNING!
Possibly hazardous optical radiation emitted from this product. Do not
look at operating lamp. Eye injury may result.
Removing the cover from the BlueWave QX4 V2.0 controller may result in electrical
shock. To prevent the possibility of an electrical shock, never remove the
controller’s
cover
The controller is cooled by natural convection. If you block the air flow from the
controller, equipment damage and malfunction can result. To prevent damage and
malfunction, ensure adequate space around controller vents to allow the free flow of
air. Typically, 1.5 in of space around all sides of the controller is sufficient.
Dymax UV Light-Curing System Safety Considerations
Operators must understand these three concepts to use the LED light source safely:
UV exposure, high-temperature surfaces, and bright, visible light.
UV Exposure
Figure 1.
UV Spectrum
Standard Dymax UV light-curing systems have been designed primarily to emit UVA
and Visible energy (Figure 1). Depending on the type of LED head used, the energy
emitted from the BlueWave QX4 V2.0 can either be in the upper end of the UVA
portion of the spectrum (PrimeCure
®
& RediCure
®
) or in the lower portion of the visible
spectrum (VisiCure
®
). UVA energy is generally considered the safest of the three UV