U S E R G U I D E
|
B L U E W A V E
®
Q X 4 V 2 . 0
37
After checking the connections and power, the administrator should check the alarm
messages in the system information window. Then, the administrator should follow the
suggestions in LCD error message indication to find solution.
Table 1.
LCD Alarm Message Indication
Message in alarm
Trigger condition
Suggestions
Ctrl Over
Temperature.
The QX4_V2.0 controller
internal temperature is
higher than maximum.
1.
The ambient temperature
around the controller
should not exceed 40°C.
2.
Check the controller’s
ventilation to cool down it.
EM x(1,2,3,4) wand
not installed.
The LED head is not
connected correctly.
Check the connections of
the LED heads and reinstall
the LED heads.
Ctrl Voltage
abnormal.
The input voltage is too low.
Check the power input
connection and power
adapter.
EM x(1,2,3,4) wand
over temperature
。
The LED head
’s temperature
is too high.
1.
The ambient temperature
around the LED Heads
should not exceed 40°C
2.
Check the LED heads
’
ventilation to cool down it.
EM x(1,2,3,4) wand
over current.
The LED head
’s output
current is over maximum.
Contact Dymax for technical
support.
EM x(1,2,3,4) wand
output not match
setting.
The
LED head’s output
current is 0A.
Contact Dymax for technical
support.