SPECIFICATIONS 

 

Specification 

PN 38920 

PN 38925 

Voltage 

230 Vac., 50Hz 

115 Vac., 60 Hz 

Current 

1 Amp 

2 Amp 

Fuse 

F2 Amp 

F3 Amp 5 x 20 mm IEC 127 

Bulb/Reflector 

50 Watt (pre-focused) 

50 Watt (pre-focused) 

Shutter Timer 

. 01 to 99.9 sec. electronic 

programmable 

. 01 to 99.9 sec. electronic 

programmable 

Foot Switch 

Rocker type 

Rocker Type 

Hour-Meter 

LCD, bulb hours 

LCD, bulb hours 

Dimensions (L X W X H)                     

12.0” X 12.25” X 6.5” 

(30.5cm X 31.1cm X 16.5cm) 

12.0” X 12.25” X 6.5” 

(30.5cm X 31.1cm X 16.5cm) 

Weight                                                 

21 lbs. (9.5 kg) 

21 lbs. (9.5 kg) 

 
 
 

Wavelength 

Output Intensities (Typical)**

 

320-390 nm 

3.0+ W/cm² 

390-450 nm 

3.5+ W/cm

 

280-320 nm 

   1 W/cm

2

 

 

** Measured with an EIT Spotcure Radiometer or Accu-Cal 50 radiometer using a Lightguide 

Simulator 

and standard internal “Cool Blue” filter. 

† Operating the unit at less than rated input voltage may yield less output intensity. 

 
 
 

BlueWave 50 spectral output 

0

0.02

0.04

0.06

0.08

0.1

0.12

0.14

0.16

0.18

0.2

282

305

328

351

374

397

420

443

466

489

Wavelength

Abs

olute I

rradiance

 

Figure 3. 

50W Spectral Chart 

Summary of Contents for BlueWave 50

Page 1: ...BlueWave 50 shown with single Lightguide BlueWave 50 UV Light Curing Spot Lamp System Operation Manual System Discontinued 2 15 2011 ...

Page 2: ...npacking and Inspection Page 4 Safety Page 5 General Page 8 Specifications Page 9 Installation and System Interconnect Page 10 Operation Page 12 Maintenance Page 14 Troubleshooting Page 15 Spare Parts List Page 16 Definition of Terms Page 17 Warranty Page 18 ...

Page 3: ...ndividual components Par conséquent nous vous encouragez a lire comprend et suivre tout sécurité et instructions d opération et conseillations rédiger dans cette et autre manuels etablir un lien avant de mettre en place et de faire marcher cette nouveau système de lampe de tache ou cettes composants individuel If you encounter a problem have any questions or would like to help us with your suggest...

Page 4: ...oxes for contents and record any serial numbers for further reference You may wish to retain the original shipping cartons in case you need to repackage any item for return If you observe or experience any problem with your equipment notify DYMAX Customer Support your authorized distributor or your DYMAX Representative immediately Figure 2 BlueWave 50 Unpacking Diagram NOTE Lamps are shipped with ...

Page 5: ...e touche quand l élément est en opération ACHTUNG Tragen Sie immer eine Sicherheitsbrille oder einen Gesichtsschutz wenn Sie nahe an der UV Lichtquelle arbeiten Die Rückseite des Gerätes emittiert gestreutes UV Licht WARNHINWEIS Bitte beachten Sie immer die Sicherheitshinweise ACHTUNG Gefahr eines Stromschlages bei geöffnetem Gehäuse ACHTUNG Gehäuse erwärmt sich während des Betriebs Vorsicht bei B...

Page 6: ...uhe BITTE BEACHTEN SIE Durch den installierten inneren Filter strahlt die BlueWave 200 UVA und sichtbares Licht aus Schauen Sie deshalb niemals direkt in die Lichtquelle wenn das Gerät angeschaltet ist DYMAX UV LIGHT CURING SYSTEM SAFETY CONSIDERATIONS DYMAX UV light curing technology has been used successfully for over 30 years The fast cure one component nature of our UV light curing technology ...

Page 7: ...ks UV light can be used as a shield to protect workers from stray UV light The following materials can be used to create simple shielding structures or blind corners Sheet Metal Aluminum steel stainless steel etc Sheet metal should be coated black or black anodized to minimize reflection of UV and visible light toward operators Rigid Plastic Film Transparent UV blocking plastics typically polycarb...

Page 8: ...on Bulb Reflector Assembly Internal Light Filter for extended Lightguide life Thermostatically Controlled Cooling Fans Lightguide Mount Bulb Status Indicator Light non resettable Hour Meter and Shutter system The Lightguide is separate and plugs into the Lightguide Holder WARNING Engage the Lightguide in the Lightguide Mount before the light is turned on and remove the Lightguide from the Lightgui...

Page 9: ... H 12 0 X 12 25 X 6 5 30 5cm X 31 1cm X 16 5cm 12 0 X 12 25 X 6 5 30 5cm X 31 1cm X 16 5cm Weight 21 lbs 9 5 kg 21 lbs 9 5 kg Wavelength Output Intensities Typical 320 390 nm 3 0 W cm 390 450 nm 3 5 W cm2 280 320 nm 1 W cm2 Measured with an EIT Spotcure Radiometer or Accu Cal 50 radiometer using a Lightguide Simulator and standard internal Cool Blue filter Operating the unit at less than rated inp...

Page 10: ...unt Figure 6 A hex wrench is provided with the BlueWave 50 for this purpose The setscrew should be tightened gently to prevent damaging the Lightguide IMPORTANT To ensure that proper output of the system is obtained be sure to completely insert the Lightguide into the Lightguide Mount prior to tightening the Setscrew Be sure to lightly tighten the Setscrew to ensure the Lightguide remains in place...

Page 11: ... Power Cord is unplugged from the rear of the unit 2 If the unit was previously running allow the Bulb to cool 10 15 minutes 3 Remove the top cover from the BlueWave 50 by loosening the four cover fasteners 4 Disconnect the Bulb Plug Figure 8 5 Loosen the two Thumbscrews and lift the Bulb Retaining Clip Figure 8 6 Remove the Bulb Reflector Assembly Figure 9 7 Install the new bulb by reversing step...

Page 12: ...Indicator Gate Input Indicator Key Protect Indicator Output Indicator Preset Value Set Value and Timing Operation Indicator A brief description of each display and location Power Indicator Displays PW in upper left corner of Timer Display Displayed when external power for operation is present Signal Input Indicator Displays SIG in upper left corner of Timer Display located to right of Power Indica...

Page 13: ... Receptacle located on the rear of the unit can be used to control the operation of the Shutter with a PLC 2 The simplest way is to disconnect the Footswitch from the Cable This frees up the Cable for use with a PLC 3 To use a PLC computer or similar control device with the BlueWave 50 the Control Device must be isolated Isolation can be achieved with use of a Relay Most PLC s provide Relay output...

Page 14: ... cleaned periodically to prevent dust buildup from affecting airflow through the unit Spare Fan Filters are provided with each unit and with replacement Bulbs The Fan Filters are washable and may be reused Remove the Fan Filter by removing the snap on cover from the rear of each grill Figure 13 Exhaust Fans with Fan Filters Removed Figure 14 Disassembled Fan Filter FUSE REPLACEMENT The unit has tw...

Page 15: ...eplace the Fuse if defective Low Output Intensity or Fails To Cure Adhesive In Allotted Time Bulb beyond useful life Use a Radiometer DYMAX ACCU CAL 50 or equivalent to measure output intensity Replace the Bulb reflector assembly if beyond useful life typical 2 000 hours Transmission loss in light guide too great Compare Lightguide output against new Lightguide or use the DYMAX Lightguide Simulato...

Page 16: ...Inlet 37178 PC Board Filter Footswitch Assembly 38791 Shutter 38544 Solenoid Assembly 38628 Switch Manual Timer 35384 Switch Power 36288 Timer Digital 36287 OPTIONS ACCESSORIES ITEM PART Case with Foam 38679 Liquid D Lightguide 5 mm X 1 Meter 5720 Liquid D Lightguide 5 mm X 1 5 Meter 5721 Liquid D Lightguide 8 mm X 1 Meter 5722 Liquid D Two Pole Lightguide 3 mm X 1 Meter 38476 Liquid D Three Pole ...

Page 17: ... 1 Ultraviolet A UV A UV of long wavelength from within approximately 400 to 320 nm of the spectral band 4000 to 3200 predominately produced by DYMAX Flood Lamps 2 Ultraviolet B UV B UV of medium wavelength from within approximately 320 to 280 nm DYMAX Flood Lamps produce some amount of their energy within this bandwidth 3 Ultraviolet C UV C UV of short wavelength below 280 nm we say from 280 to 2...

Page 18: ...ED TO THIS AUTHORIZATION DYMAX offers a one year warranty against defects in material and workmanship on all system components except the Bulb with proof of purchase date Unauthorized repair modification or improper use of equipment may void warranty The use of aftermarket replacement parts not supplied or approved by DYMAX Corporation will void any effective warranties and may result in damage to...

Page 19: ...BlueWave 50 Light Curing Spot Lamp 19 NOTES ...

Page 20: ...g equipment trial rental and leasing programs to assist in such testing and evaluation Data sheets are available for valve controllers or pressure pots upon request MAN017 PN 38907 12 03 2010 Dymax Corporation 1 860 482 1010 info dymax com www dymax com Dymax Oligomers Coatings 1 860 626 7006 info_oc dymax com www dymax oc com Dymax Asia H K Limited 852 2460 7038 dymaxasia dymax com www dymax com ...

Reviews: