Dymax BlueWave® LED DX-1000 VisiCure® User Guide
Operating the LED Light
WARNINGS!
Looking directly at the high-intensity light emitted by the BlueWave LED
DX-1000 VisiCure can result in eye injury. To prevent eye injury, never look directly at the high-
intensity light and always wear protective goggles (provided).
Operating the light with the lens cover in place can result in overheating and equipment damage.
To prevent equipment damage, never operate the unit with the lens cover in place.
Powering up the Controller
Follow these steps to operate the
BlueWave LED DX-1000 VisiCure
system:
1.
Move the Power Switch on the Back Panel of the Controller to the On (I) position. The Power Supply
and Timer are now operational.
2.
Activate an exposure cycle by pressing the Footswitch or the Run Button on the Controller Front
Panel (Figure 10).
3.
In manual mode (all timer digits will be dashes), the exposure time is controlled directly from the
Footswitch. In timed mode, operation is determined by the setting displayed on the Cycle Time
Display.
4.
To adjust the exposure time, push the Cycle Time Adjustment Buttons (Figure 10) to enter the desired
number of seconds the LED needs to be powered. The up arrow (
) increases the cycle (exposure)
time in 0.1 second increments. Note that holding the up arrow increases the rate of change of the
digits. The down arrow (
) decreases the cycle (exposure) time in 0.1 second increments.
5.
The output intensity can be adjusted from 5 to 100% in 1% increments using the light intensity up
arrow (
▲
) or down arrow (
▼
). Press the Timed/Manual Mode Button to place the unit in manual
mode and then adjust the intensity using the Intensity Adjustment Buttons. Output intensity cannot
be adjusted in the timed mode.
Figure 10. Front Control Panel
Intensity Control
Feature. See Intensity
Control Feature
Cycle Time
Adjustment Buttons
Run/Stop Button
Timed/Manual
Mode Button
Cycle Time Display