Dymax BlueWave® LED DX-1000 VisiCure® User Guide
Front Control Panel
In addition to the Light Intensity Control Feature, the Front Control Panel (Figure 4) includes:
■
Run/Stop Button
—
Pressing this button starts a curing cycle. In timed operation, pressing and releasing
the Run/Stop Button illuminates the curing light for the length of time displayed in the Cycle Time Display.
A second press will stop the cure cycle immediately. In manual operation, pressing and holding the
Run/Stop Button illuminates the curing light until the button is released. The curing light illuminates until
the cycle time is reached.
■
Timed/Manual Button
—
Pressing this button toggles between manual and automatic operation. In timed
operation, pressing the Run/Stop Button illuminates the curing light for the length of time displayed in the
Cycle Time Display. In manual operation, the Cycle Time Display changes to a series of dashes and the
curing light remains illuminated as long as the Run/Stop Button is depressed.
■
Cycle Time Display
—
This LED display indicates the current cycle time. It also displays the light intensity
percentage when light intensity is adjusted. It also will display error codes if an operating error occurs.
■
Cycle Time Adjustment Buttons
—
Pressing these buttons increases or decreases the cycle time. Hold
the button in to increase the speed at which the value changes.
■
Intensity Control Feature
—
Enables manual control of the light intensity (see
Intensity Control Feature
on page 8). Pressing the + or
–
button momentarily will change the display to show the current setting in
%, holding the button will increase or decrease the setting and the display will show the set level as it is
adjusted.
■
Operating Time Log
(unit operation and exposure hours (non re-settable))
—
This display is only visible
when both the + and
–
time buttons are pressed and held simultaneously for 5 seconds. The display will
indicate in hours the accumulated run time of the LED first and then the Controller second.
Figure 4. Front Control Panel
Intensity Control
Feature. See Intensity
Control Feature
page 8.
Cycle Time
Adjustment
Buttons
Run/Stop Button
Timed/Manual
Button
Cycle Time &
Digital Intensity
Display