D2366 GSM Radio Signal Analyser – Operation Manual – D2366-OPS2/EU/F10/v4 -
15
Operation – MONITOR (cont’d)
Detailed View
This screen is
only
available in
Engineer
Mode.
From the Monitor menu, press the up arrow to get to the Detailed View screen:
Advanced (in Setup) = OFF
Advanced (in Setup) = ON
NETWORK
The network to which the cell belongs, e.g. Vodafone
GSM
900 or 1800 MHz
The radio frequency band used by the displayed cell
Radio signals using 900MHz penetrate better into buildings
BSIC
Base Station Identity Code – identifies the beacon frequency
CELL
Cellular identification number of the cell
SIM
Not Fitted or Status
dBm
FSSI Signal Strength – scale = decibels ref to 1 mW
CSQ
FSSI Signal Strength – scale = 0 – 31 (12 and above is acceptable)
BAT
% = charge remaining in battery – 100% = fully charged
EXT = charger connected
Min
The minimum signal strength measured on this cell, if the cell number
changes this value is reset.
Max
The maximum signal strength measured on this cell, if the cell number
changes this value is reset.
BAT
% = charge remaining in battery – 100% = fully charged
EXT = charger connected
Jamming Detection
If a jamming signal is detected, <<JAMMING>> will be displayed on the Monitor screen.
Operation – SCREENSAVER