background image

D18XX Series PoE Midspan 4 to 16 ports - Installation Manual - D18XX-INST /11E/v1                                           Page 4 of 6 

 

 

 

 

4 Technical 

Specifications 

 

Part Number 

 

D1804 - 4 ports

 

D1808 - 8 ports

 

D1812 - 12 ports

 

D1816 - 16 ports

Power Available 

 

Max. 120 watts 

Max. 240 watts 

Max. 360 watts 

Max. 480 watts 

Max. Input 
Current at 230V

 

0.65A 

1.3A 

1.95A 

2.6A 

AC Power Supply 
Voltage

 

207V to 253V 

AC Input

 

49Hz to 61Hz 

Network Inputs 

 

10/100 Base-T 

Outputs

 

54V nominal, +/- 3%  

Port Power 
Output  

 

35W (630mA at 55.5V) maximum 

Fuse Rating 

 

Time delay T6.3A 20mm fuse, 250 V 

Operating 
Temperature 
Range   

-10°C to +40°C 

 

Size (L x W x D) 

485mm

 

x

 

285mm

 

x

 

90mm

 

Weight 

4kg  4.3kg 4.6kg 4.9kg 

 

5  Safety and environmental Information 

5.1 Equipment Modifications 

This equipment must be installed and used in strict accordance with the instructions given in this 
manual.  This equipment contains no user-serviceable components.  Unauthorised changes or 
modifications to this equipment will invalidate all applicable regulatory certifications and approvals. 

Every care has been taken in the preparation of this manual.  Please inform us of any inaccuracy or 
omission.  Dycon Ltd cannot be held responsible for any technical or typographical errors and 
reserves the right to make changes to the product and manuals without prior notice. 

All manuals and user guides at all-guides.com

Summary of Contents for d1800 Series

Page 1: ...wer PoE Midspan Power Supply Dycon Ltd Tel 44 0 1443 471 060 Fax 44 0 1443 479 374 Cwm Cynon Business Park Mountain Ash CF45 4ER UK www dyconsecurity com info dyconsecurity com All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...d powered device and individual ports are over current protected according to the class of the connected device 2 1 Features IEEE 802 af and IEEE 802 at Type 1 and Type 2 compliant Power supply better than 85 efficient at full load Genuine full power available simultaneously across all ports Fully automatic powered device signature detection and power limiting 4 to 16 port model variants available...

Page 3: ...rs and the output with injected power is connected to the corresponding upper data and power output connector 1 Check the unit is plugged in and switched on at the rear of the unit The yellow standby LEDs on the front modular connectors will be illuminated indicating that power is available 2 Connect the Ethernet data cables to the bottom row data inputs 3 Connect the cable to the powered device t...

Page 4: ...40 C Size L x W x D 485mm x 285mm x 90mm Weight 4kg 4 3kg 4 6kg 4 9kg 5 Safety and environmental Information 5 1 Equipment Modifications This equipment must be installed and used in strict accordance with the instructions given in this manual This equipment contains no user serviceable components Unauthorised changes or modifications to this equipment will invalidate all applicable regulatory cert...

Page 5: ...Peru IT equipment cannot power this device In the case of an IT powered device the unit needs to be powered by 230V through an isolation transformer with a ratio of 1 1 and the secondary connection Neutral is properly grounded 5 3 Precautions Please read the following carefully before installing and connecting the system to a power source 1 Only qualified and trained service personnel in accordanc...

Page 6: ...trical and Electronic Equipment directive 5 6 Electromagnetic Compatibility EMC This digital equipment fulfils the requirements for radiated emission according to limit B of EN55022 1998 and the requirements for immunity according to EN55024 1998 residential commercial and light industry 6 Support Trouble shooting In case you require any technical assistance please contact Dycon Technical Support ...