background image

 

 

 

Installation Manual for     

D1800 Series  

High Power PoE Midspan 

Power Supply 

 

 

 

 

 

 

 

 

 

Dycon Ltd 

Tel: +44 (0)1443 471 060 - Fax: +44 (0)1443 479 374 

Cwm Cynon Business Park – Mountain Ash – CF45 4ER - UK 

www.dyconsecurity.com

  ‐  

[email protected]

 

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for d1800 Series

Page 1: ...wer PoE Midspan Power Supply Dycon Ltd Tel 44 0 1443 471 060 Fax 44 0 1443 479 374 Cwm Cynon Business Park Mountain Ash CF45 4ER UK www dyconsecurity com info dyconsecurity com All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...d powered device and individual ports are over current protected according to the class of the connected device 2 1 Features IEEE 802 af and IEEE 802 at Type 1 and Type 2 compliant Power supply better than 85 efficient at full load Genuine full power available simultaneously across all ports Fully automatic powered device signature detection and power limiting 4 to 16 port model variants available...

Page 3: ...rs and the output with injected power is connected to the corresponding upper data and power output connector 1 Check the unit is plugged in and switched on at the rear of the unit The yellow standby LEDs on the front modular connectors will be illuminated indicating that power is available 2 Connect the Ethernet data cables to the bottom row data inputs 3 Connect the cable to the powered device t...

Page 4: ...40 C Size L x W x D 485mm x 285mm x 90mm Weight 4kg 4 3kg 4 6kg 4 9kg 5 Safety and environmental Information 5 1 Equipment Modifications This equipment must be installed and used in strict accordance with the instructions given in this manual This equipment contains no user serviceable components Unauthorised changes or modifications to this equipment will invalidate all applicable regulatory cert...

Page 5: ...Peru IT equipment cannot power this device In the case of an IT powered device the unit needs to be powered by 230V through an isolation transformer with a ratio of 1 1 and the secondary connection Neutral is properly grounded 5 3 Precautions Please read the following carefully before installing and connecting the system to a power source 1 Only qualified and trained service personnel in accordanc...

Page 6: ...trical and Electronic Equipment directive 5 6 Electromagnetic Compatibility EMC This digital equipment fulfils the requirements for radiated emission according to limit B of EN55022 1998 and the requirements for immunity according to EN55024 1998 residential commercial and light industry 6 Support Trouble shooting In case you require any technical assistance please contact Dycon Technical Support ...