background image

- 6 -

• Disconnect the Cable from the Drain by threading the Cable Connector 

(1)

 counter-clockwise. 

Fig. A.

•  Look at the area on the Drain Body where the Cable was attached and locate the component labeled as 

“Cam” in the illustration. 

Fig. B.

•  Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the 

Stopper should be in the UP position. 

Fig. B, C. 

• Push DOWN on the Lift-Knob to make sure it is fully down. 

Fig. C.

•  Re-attach the Cable to the Drain Body Connection

 (2)

 by threading the Cable Connector 

(1)

 clockwise onto the 

Drain Body Connection 

(2)

 and hand-tighten. 

Fig. A.

• Disconnect the Cable from the Drain by threading the Cable Connector

 (1)

 counter-clockwise. 

Fig. A.

•  Look at the area on the Drain Body where the Cable was attached and locate the component labeled 

as “Cam”  and “Cam Cap” in the illustration. 

Fig. B.

• Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain.

 Fig. D.

• Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. 

Fig. E.

• The Stopper can now be removed by lifting it out of the Drain. 

Fig. F.

If sink does not hold water even though Stopper is in the “down” position:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If Stopper does not raise up fully or sink drains too slowly:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If you need to remove the Stopper:

     • Follow STOPPER REMOVAL PROCEDURE.

If you would like the ability to remove your Stopper simply by lifting it out of the drain:

     • Follow STOPPER INSTALLATION PROCEDURE for 

“Unlocked” mode

.                                                                       

CABLE ADJUSTMENT PROCEDURE

STOPPER REMOVAL PROCEDURE

Speed Connect

®

 Drain

Troubleshooting Guide

Fig.

 

F.

CAM

CAM CAP

Fig.

 

B.

Fig.

 

A.

REMOVE

CAM

Fig.

 

E.

2

1

RE-ATTACH

DISCONNECT

Fig.

 

D.

REMOVE

CAM CAP

Fig.

 

C.

DOWN

STOPPER

Fig.

 

F.

CAM

CAM CAP

Fig.

 

B.

Fig.

 

A.

REMOVE

CAM

Fig.

 

E.

2

1

RE-ATTACH

DISCONNECT

Fig.

 

D.

REMOVE

CAM CAP

Fig.

 

C.

DOWN

STOPPER

M965497 Rev. 1.6 (5/17)

Summary of Contents for Rem D35100330

Page 1: ... 2 to 6 64 to 152 mm 2 1 2 to 6 64 to 152 mm 2 51 mm 1 1 8 D 29 mm 1 1 8 D 29 mm 7 MAX 178 mm 2 MAX 51 mm 2 1 8 DIA 54 mm 1 1 4 O D 32 mm 13 MAX 330 mm 4 MAX 102 mm SPRAY CONNECTIONS ARE FOR 1 2 IPS FLEXIBLE SUPPLIES or 3 8 O D BULL NOSE RISERS 3 75 mm In the United States DXV One Centennial Avenue Piscataway New Jersey 08855 Attention Director of Customer Care For residents of the United States w...

Page 2: ... 9 onto MOUNTING NUT 8 until snug against bidet ledge INSTALL TRANSFER VALVE CAUTION Turn off hot and cold watert supplies before beginning 2 FRONT 4 1 3 5 18 14 15 19 17 16 6 7 13 20 12 10 11 8 9 COLD HOT BIDET LEDGE GROOVE APPLY TEFLON TAPE 10 10 1 1 2 38 mm MAX 3 5 4 2 1 Unpack valve assembly and remove HANDLE 10 by unthreading SET SCREW 11 Unthread ROSETTE 12 and FLANGE 13 removing them from V...

Page 3: ...ASTIC COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Tighten TAILPIECE 4 on DRAIN BODY before installing DRAIN BODY Fig B POP UP DRAIN DRAIN BODY 4 2 3 1 Fig A Fig B 2 3 1 4 Fig A Fig B 1 DRAIN FLANGE 1 WHITE FOAM GASKET NOT VISIBLE 1 2 4 5 3 ILLUSTRATION SHOWN LESS VALVES SLOTTED MOUNTING NUT Fig B Fig B Fig A Thread FLANGE 1 counter clockwise and remove FLANGE 1 and FOAM GASKET 2 fr...

Page 4: ...rger end to each VALVE OUTLET Important Loop SUPPLY HOSES 1 as illustrated so they do not kink INSTALL SPRAY BODY Apply putty to the underside of SPRAY BODY FLANGE 3 and install SPRAY BODY 3 into spray hole of Bidet From underside of Bidet install RUBBER WASHER 4 FIBER WASHER 5 and LOCKNUT 6 onto shank of SPRAY BODY 3 Tighten LOCKNUT 6 to make water tight seal Connect one end of SPRAY HOSE 7 to HO...

Page 5: ... Turn diverter to rim wash and bidet spray Operate LIFT ROD 2 and fill bidet with water DRAIN STOPPER 3 should make a good seal and retain water in bidet If DRAIN STOPPER 3 does not make a water tight seal see Troublingshooting Guid section in these instructions Release DRAIN STOPPER 3 and check all drain connections and P trap for leaks Tighten if necessary NOTE Diverter valve is not a positive s...

Page 6: ...n Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F If sink does not hold water even though Stopper is in the down position Follow CABLE ADJUSTMENT PROCEDURE If Stopper does not r...

Page 7: ...JUSTMENT PROCEDURE in Troubling Shooting Guide to complete installation Stopper will be in Locked mode and not be removable UNLOCKED MODE Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink Rotate St...

Page 8: ...RTER COVER H961251 XXX ROSETTE H960849 XXX ROSETTE H961260 191 MOUNTING KIT H960568 XXX AERATOR ASSEMBLY H961248 191 MOUNTING KIT 028704 0070A TEE AND HOSE KIT INCLUDING SEALS M921323 0070A ELBOW ADAPTER M964550 YYY0A POP UP KNOB AND ROD H961247 XXX SPRAY BODY H961249 191 HOSE ASSEMBLY M952430 0070A CABLE ASSEMBLY H960742 191 1 2 SIDE VALVE ROUGH CLOCK WISE ON H960741 191 1 2 SIDE VALVE ROUGH COUN...