- 1 -
INSTALLATION INSTRUCTIONS
SA
VE FOR FUTURE USE
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2017
7302328-100 (3/17)
Thank you for selecting DXV. To ensure this product is installed properly, please read these instructions carefully before you begin.
(Certain installations may require professional help.) Also be sure your installation conforms to local codes.
CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!
NOTE: Pictures may not exactly define contour of china and components.
!
Lowell
™
One-Piece Toilet — 1.28 gpf / 4.8 Lpf
Model# D22010C104.415
Gasket
Wax Ring
Regular Screwdriver
10'
Level
Flexible Supply Tube
Closet Bolts
Putty Knife
Tape Measure
Hacksaw
Sealant
Adjustable Wrench
a.
Close toilet supply valve and flush tank completely. Towel or sponge remaining water from tank and bowl.
b.
Disconnect and remove supply line.
NOTE:
If replacing valve, first shut off main water supply!
c.
Remove old mounting hardware, remove toilet and plug floor waste opening to prevent escaping sewer gases.
d.
Remove closet bolts from flange and clean away old wax, putty, etc. from base area.
NOTE:
Mounting surface must be clean and level
before
new toilet is installed!
IMPORTANT:
Water supply on the wall is required at 3-3/4" (95mm) or 9" (299mm) from centerline of the toilet (see rough-in).
First suggested position is hidden behind the toilet. The geometry of the toilet gives space for this installation. The second
suggested position is next to the toilet. Between these two positions, the space for the supply between wall and toilet is
limited to 4-1/8" (105mm). In this case, check your supply and hose dimensions.
1
2
REMOVE OLD TOILET
ROUGHING-IN DIMENSIONS:
NOTE:
Distance from wall to
closet flange centerline must
be as listed below:
ALL INSTALLATION PROCEDURES MUST COMPLY IN STRICT ACCORDANCE WITH APPLICABLE LOCAL
PLUMBING AND BUILDING CODES
3/4" (18 mm)
8-3/4"
(223 mm)
12"
(305 mm)
13-1/8"
(333 mm)
C/L OF OUTLET AND
TOILET MTG BOLTS
27-11/16"
(703 mm)
FINISHED WALL
29-11/16"
(754 mm)
7-1/16"
(180 mm)
7"
(178 mm)
15-3/8"
(391 mm)
11/16"
(17mm)
18-1/2"
(470 mm)
C/L OF SEAT POST
MTG HOLES ON
5-1/2" (140 mm) CTRS
1-15/16"
(49 mm)
3-5/16"
(85 mm)
SUPPLY AS
REQUIRED
(position 1
or
position 2)
C/L
10-9/16"
(269 mm)
9"
(229 mm)
3-3/4"
(95 mm)
14"
(356 mm)
15"
(381 mm)
RECOMMENDED TOOLS AND MATERIALS
Most of the procedures require the use of common tools and materials, which are available from hardware and plumbing
supply stores. It is essential that the tools and materials be on hand before work is begun.